Laserfiche WebLink
ILLUMINATION SUMMARY <br />Not to be reproduced in whole or part without the written consent of Musco <br />Sports Lighting, LLC. ©1981, 2014 Musco Sports Lighting, LLC. <br />ENGINEERED DESIGN <br />By:Treana Drost <br />File # / Date:162245B 17-Dec-14 <br />41 <br />44 <br />45 <br />49 <br />47 <br />40 <br />54 <br />51 <br />50 <br />45 <br />39 <br />48 <br />45 <br />46 <br />39 <br />39 <br />48 <br />44 <br />46 <br />38 <br />43 <br />52 <br />50 <br />48 <br />40 <br />46 <br />53 <br />48 <br />47 <br />45 <br />T5 <br />T6 <br />50' <br />6 <br />0 <br />' <br />50' <br />7 <br />0 <br />' <br />60' <br />6 <br />8 <br />' <br />60' <br />7 <br />2 <br />' <br />T4 <br />T3 <br />SCALE IN FEET 1 : 60 <br />0'60'120' <br />EQUIPMENT LIST FOR AREAS SHOWN <br />Pole Luminaires <br />QTY LOCATION SIZE GRADE <br />ELEVATION <br />MOUNTING <br />HEIGHT <br />LAMP <br />TYPE <br />QTY / <br />POLE <br />THIS <br />GRID <br />OTHER <br />GRIDS <br />2 T3-T4 50'-50'1500W MZ 4 2 2 <br />2 T5-T6 50'-50'1500W MZ 2 2 0 <br />4 TOTALS 12 8 4 <br />Pole locaƟon(s)dimensions are relaƟve <br />to 0,0 reference point(s) <br />MY PROJECT <br />Name:Red Morton Park Phase 2 <br />LocaƟon:Redwood City,CA <br />GRID SUMMARY <br />Name:Tennis 3-4 <br />Size:2 Court - 12' Spacing <br />Spacing:20.0' x 20.0' <br />Height:3.0' above grade <br />CONSTANT ILLUMINATION <br />SUMMARY HORIZONTAL FOOTCANDLES <br />EnƟre Grid <br />Guaranteed Average:40 <br />Scan Average:45.7 <br />Maximum:54 <br />Minimum:38 <br />Avg / Min:1.20 <br />Guaranteed Max / Min:2 <br />Max / Min:1.42 <br />UG (adjacent pts):0.00 <br />CU:0.51 <br />No. of Points:30 <br />LUMINAIRE INFORMATION <br />Luminaire Type:Green GeneraƟon <br />Design Usage Hours:5,000 hours <br />Design Lumens:134,000 <br />Avg Lamp Tilt Factor:1.000 <br />No. of Luminaires:8 <br />Avg KW:12.51 (13.6 max) <br />Guaranteed Performance:The Guaranteed Average <br />CONSTANT ILLUMINATION described above is guaranteed <br />for the design usage hours of the system. <br />Field Measurements:IlluminaƟon measured in accordance with <br />IESNA LM-5-04 and CIBSE LG4. Individual values may vary. <br />See the Warranty document for details. <br />Electrical System Requirements:Refer to Amperage <br />Draw Chart and/or the "Musco Control System Summary" <br />for electrical sizing. <br />InstallaƟon Requirements:Results assume +/- 3% <br />nominal voltage at line side of the ballast and structures <br />located within 3 feet (1m) of design locaƟons. <br />NOTES:Circles shown are approx. locations of existing <br />poles. <br />8. <br />A <br />. <br /> <br />- <br /> <br />P <br />a <br />g <br />e <br /> <br />1 <br />0 <br />7 <br />