My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
Agmt01 Pacific Shores De... (3)
RedwoodCity
>
City Clerk
>
Agreements
>
2000-2009
>
2001
>
Agmt01 Pacific Shores De... (3)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/18/2005 12:01:23 PM
Creation date
5/2/2002 12:03:38 PM
Metadata
Fields
Template:
Agreement
Contractor Name
Pacific Shores Development
PROJECT NAME
1100-2100 Seaport Blvd (lots A-H) improvements
RMP File Number
304
Date
5/14/2001
Reso Ref
14152
Box
5940
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
18
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
<br />described in accordance with, and as provided for in, the plans prepared for Owner by Bohley <br /> <br />Consulting Civil Engineers, entitled, "Construction Drawings for Pacific Shores Center Lots A- <br /> <br />H," as well as City's revised specifications entitled, "Engineering Standards of the City of <br /> <br />Redwood City", adopted January 5, 1998 which plans and specifications are on file in the office <br /> <br />of the City Engineer, Engineering and Construction. <br /> <br />Said Improvements shall also be <br /> <br />constructed in strict compliance with the provisions of Article VII, Chapter 29 of the Code of the <br /> <br />City of Redwood City. If a conflict exists between the plans and specifications and said Chapter <br /> <br />29 in regard to the standard for a particular improvement, the stricter standard shall govern to <br /> <br />the extent of such conflict. Owner shall complete all of the Improvements to Lots A, B, C, D, <br /> <br />and a portion of H, subject to such exceptions and time extensions allowable under paragraph <br /> <br />10, prior to occupancy of the buildings (See Exhibit "A", attached). The Improvements shall <br /> <br />include, but are not necessarily limited to, all of the following: <br /> <br />(a) <br />(b) <br /> <br />(c) <br /> <br />(d) <br /> <br />(e) <br /> <br />(f) <br /> <br />(g) <br /> <br />(h) <br /> <br />grading, paving <br /> <br />curbs, gutters, sidewalks <br /> <br />water system, complete <br /> <br />sewer system, complete <br /> <br />storm drainage system, complete <br /> <br />landscaping and irrigation system, complete <br /> <br />signing, striping, markings, complete <br /> <br />site lighting, complete <br /> <br />and all other work, improvements, or construction required by or mentioned in the above- <br /> <br />mentioned plans and specifications, conditions of permits and all construction, appurtenances, <br /> <br />and improvements necessary as reasonably determined by the City Engineer, Engineering and <br /> <br />Construction to complete the aforementioned improvements. <br /> <br />Agmt-447 <br />F:\sh\sh\Redwood\Council <br />FXS:djk <br />02/13/01 <br /> <br />2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.