My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
AgdaPkt 2016-11-28 Closed and Joint SA PFA
RedwoodCity
>
City Clerk
>
Agenda Packets
>
2010-2019
>
2016
>
AgdaPkt 2016-11-28 Closed and Joint SA PFA
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/29/2016 1:43:27 PM
Creation date
11/22/2016 12:36:48 PM
Metadata
Fields
Template:
CC Index
CC Index - Document Type
Agenda Packet
Meeting Type
Joint
Agency Type
City Council and Successor Agency and Public Financing Authority
Date
11/28/2016
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
432
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
ATTY/ORD.433/BUILDING CODE ADOPTION <br />REV: 10-24-16 RL <br />Page 8 of 16 <br />Under habitable rooms of Groups R occupancies, a vapor barrier approved by the <br />Building Official shall be installed beneath the concrete slab floor. Single-ply plastic <br />vapor barriers shall not be used. An approved base material of suitable <br />consistency, compaction, and thickness shall be provided directly under the <br />concrete slab vapor barrier to retard capillary action. Two (2) inches of sand shall <br />be provided between the vapor barrier and the concrete slab. The top of the <br />concrete f loor slab shall be a minimum six (6) inches above exterior finished grade. <br /> <br />Sec. 9.65. SECTION R506.1 OF THE RESIDENTIAL CODE AMENDED: Section R506 of <br />the Residential Code is amended to add a new Section R506.1.1 to read as follows: <br /> <br />R506.1.1 Concrete slab floors. Concrete slab floors, garage slabs, and driveways <br />shall have a minimum thickness of three and one-half (3 1/2) inches and shall be <br />reinforced with a minimum six (6) inch by six (6) inch by six (6) gauge welded wire <br />fabric or equivalent area of reinforcing. W elded wire fabric manufactured in mats <br />shall be used. All reinforcement shall be appropriately supported in order to keep <br />the reinforcement in the mid-depth of the slab until the completion of the concrete <br />pour. <br /> <br />Under habitable rooms of Groups R occupancies, a vapor barrier approved by the <br />Building Off icial shall be installed beneath the concrete slab floor. Single-ply <br />plastic vapor barriers shall not be used. An approved base material of suitable <br />consistency, compaction, and thickness shall be provided directly under the <br />concrete slab vapor barrier to retard capillary action. Two (2) inches of sand shall <br />be provided between the vapor barrier and the concrete slab. The top of the <br />concrete f loor slab shall be a minimum six (6) inches above exterior finished grade. <br /> <br />Sec. 9.66. TABLE 2308.5.11, GYPSUM SHEATHING IN THE TABLE OF THE <br />BUILDING CODE AMENDED: Table 2308.5.11, Line 5 is amended to read as follows: <br /> <br />Gypsum sheathing shall not be considered for a braced wall panel . <br /> <br />Sec. 9.67. SECTION R602.10.4 OF THE RESIDENTIAL CODE AMENDED: Section <br />R602.10.4 is amended to add a new section R602.10.4.4 to read as follows: <br /> <br />R602.10.4.4. Limits on methods GB and PCP. In Seismic Design Categories D0, <br />D1, and D2, Method GB is not permitted for use as intermittent braced wall panels, <br />but gypsum board is permitted to be installed when required by this Section to be <br />placed on the opposite side of the studs from other types of braced wall panel <br />sheathing. In Seismic Design Categories D0, D1, and D2, the use of Method PCP <br />is limited to one-story single family dwellings and accessory structures. <br /> <br />Sec. 9.68. ADOPTION OF APPENDICES F, I, AND J. Appendices F, I, and J as set <br />forth in the 2016 California Building Code, are adopted by reference. <br /> <br />Sec. 9.69. SECTION J102.1, APPENDIX J OF THE BUILDING CODE AMENDED: <br />6.4.B. - Page 21
The URL can be used to link to this page
Your browser does not support the video tag.