My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
Reso PC17-01 0002 PC Reso 910 Woodside
RedwoodCity
>
City Clerk
>
Resolutions
>
Planning Commission
>
2017
>
Reso PC17-01 0002 PC Reso 910 Woodside
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/19/2017 4:50:15 PM
Creation date
1/19/2017 4:46:12 PM
Metadata
Fields
Template:
CC Index
CC Index - Document Type
Resolution
Meeting Type
Regular
Agency Type
Planning Commission
Date
1/17/2017
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
21
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
the property, the applicant shall connect the project to the recycled water system. <br />[SDR][ENGINEERING] <br />36. Dual Plumbing Report - The applicant shall hire an engineer licensed in California and <br />experienced in the field of wastewater treatment to prepare a report pursuant to California <br />Water Code section 13522.5 and in accordance with California Code of Regulations <br />sections 60314 and 60323 (found within Title 22, Division 4, Chapter 3). The report shall <br />be submitted with the first building submittal, and will be routed to the Public Works <br />Department for review and coordination. [COA][ENGINEERING] <br />37. Backflow Protection — Backflow protection on all water services is required. The <br />backflow preventer shall be above grade and located on private property, accessible to <br />the Public Works division for testing. [COA][ENGINEERING] <br />38. Fire Flow — The Project shall meet fire flow requirements as established by the Fire <br />Department which are based on the Fire Code. Fire flow tests are typically performed <br />during the preliminary design phase but must be completed prior to submittal of final <br />design. Applicant shall contact the Fire Department for fire flow requirements, and then <br />submit a written fire flow test request to Engineering. [COA][ENGINEERING] <br />39. C3 Requirements — Plans shall be designed to meet C3 requirements of the Municipal <br />Regional Permit (MRP) NPDES Permit CAS612008 and be in compliance with San <br />Mateo County C.3 Stormwater Technical Guidance. [SDR][ENGINEERING] <br />a. Treatment Controls — Treatment measures to be shown on final improvement <br />or grading plans shall not differ materially from the treatment measures <br />presented on the project's Tentative Map, approved on January 17, 2017, <br />without written approval from the Engineering Department. <br />b. Self -Treating and Self -Retaining Areas — The improvement plans shall <br />include a Drainage Area Management Plan, which shall clearly indicate which <br />areas of the site are intended to be self -treating and which are intended to be <br />self-retaining. The plan shall include adequate information to confirm that the <br />areas are designed in accordance with the C.3 Stormwater Technical Guidance <br />for each of those designated types. <br />i. In order to be considered a self -treating area, the void space in the <br />subbase/base layer (for pervious pavers) or planting media (green roof) <br />below the subdrain must have sufficient capacity in the void space to store <br />the MRP C.3.d volume of rainfall runoff for the area of pervious pavers or <br />green roof. Self -treating areas may not accept runoff from other impervious <br />areas. <br />ii. In order to be considered a self-retaining area, the subbase/base layer (for <br />pervious pavers) or planting media (green roof) below the subdrain must <br />have sufficient capacity in the void space to store the MRP C.3.d volume of <br />runoff for both the area of pervious paving/green roof and the area that <br />drains to it; however, the self-retaining area may not accept runoff from an <br />area of impervious surface that has a surface area of more than two times <br />the surface area of the pervious paving/green roof area. Any inlets or <br />ATfY/RESO.0002/PC RESO 910 WOODSIDE <br />REV: 01-11-17 PR <br />Page 10 of 20 <br />
The URL can be used to link to this page
Your browser does not support the video tag.