Laserfiche WebLink
"Section 9.54. Table No. 15-B-2 Item No. 1 of the Building Code is <br /> hereby amended <br /> to read as follows: <br /> "TABLE NO. 15-B-2 WOOD SINGLE OR SHAKE APPLICATION <br /> WOOD SHINGLES WOOD SHAKES <br /> ROOF SLOPE <br /> Not permitted below Not permitted below <br /> 3:12 4:12 (1) <br /> See Table No. 15-C See Table No. 15-C <br /> Singles and shakes shall be applied to roofs with <br /> 1. Deck Requirement solid sheathing. <br /> Sheathing shall be minimum 1/2" nominal thickness <br /> and conform to section 2326.12.9 of the Building <br /> Code. <br /> "Section 9.55. Section 1514, Appendix Chapter 15 of Building <br /> Code Amended: Section 1514, Appendix Chapter 15 of the Building Code is <br /> hereby amended to read as follows: <br /> "Section 1514. General. All reroofing shall conform to the <br /> applicable provisions of Chapter 15 of the Building Code. All materials applied <br /> as roof-covering for reroofing shall have a fire retardant rating of Class A or B in <br /> accordance with U.B.C. Standard 15-2. <br /> EXCEPTION: Existing roof with a classification less than B may be <br /> reroofed with similar material provided that the reroofed area does not exceed <br /> twenty five (25) percent of the total roof area in any one-year period. <br /> ORD-001 13 <br /> FXS:rg <br /> 10/23/95 <br /> 11/13/95R <br />