<br />- DES:d-ik 11/07/89 (029/7) <br />DES:( 11/13/89R <br /> <br /> <br /> <br />"Appendix A <br /> <br />to <br /> <br />Division 4, Article IX, Chapter 9 <br />of the Code of the City of Redwood City, California <br /> <br /> <br />"For purposes of preparing engineering reports on URM <br /> <br />buildings for the City of Redwood City, the following engineering <br /> <br />standards shall apply. <br /> <br />(a) Minimum Earthquake Forces for Structures. <br /> <br />(1) General. Except as provided in (a) (2) every structure <br />shall be designed and constructed to resist minimum <br />total lateral seismic forces assumed to act <br />nonconcurrently in the direction of each of the main <br />axes of the structure in accordance with the following <br />formula: V = ZIKCSW. The value of ZIKCS need not <br />exceed the values set forth in Table A-I based on the <br />applicable rating classification of buildings. <br /> <br />(2) Lateral Forces on Elements of Structures. Parts or <br />portions of structures shall be analyzed and designed <br />for lateral loads in accordance with subsection 2312(e) <br />of the 1985 Uniform Building Code, 1985 Edition, but <br />not less than the value from the following formula: <br />Fp = ZISCpWp. The values shown on Table A-I and the <br />value of Cp need not exceed the values as set forth in <br />Table A-2. <br /> <br />(b) Testing. Testing of URM walls utilized to carry <br />vertical loads and seismic forces shall be performed as follows: <br /> <br />(1) Mortar joints may be raked, cleaned and pointed with <br />Type S or N mortar (no masonry cements) prior to <br />testing, under the continuous observation of a deputy <br />building inspector or special inspector as defined in <br />the UBC. <br /> <br />(2) Tests may consist of in-place shear tests or core <br />tests. The minimum number of tests shall be two (2) <br />per wall or line of wall elements resisting a common <br />force, or one (1) per fifteen hundred (1500) square <br />feet of wall surface, with a minimum of eight (8) total <br />tests. Exact test or core locations shall be field- <br />determined by the civil or structural engineer <br />responsible for the engineering report. <br /> <br />(3) For each in-place shear test, the bed joints of the <br />outer wythe of the masonry shall be tested in shear by <br /> <br />15 <br /> <br />2004 <br /> <br /> <br />___ _ ~""""""",~,,,,,.,,,,_,.,,,,~_,,_,_....~.....__,,,,,,,_"".,, _"..._ '_--oA"'__~'__"~"_,___"__,,. <br />