Laserfiche WebLink
EXHIBIT "B" <br />LOCATOR WIRD MUST BE LONG ENOUGH 3' <br />TO EXPEND 2 ABOVE BOX --i <br />\. \ <br />ANGLED CIX STOP VFlN�.V�E <br />VJTIHPBRil45 WP�PLEUOR APPR01VED5EQUAL <br />POLYETHYLENE PIPQCLAS7�, <br />PE 471a N0( LgM &GS UNIONS <br />10 AWGCOPPERHEAD <br />NG WIRE <br />WITH PURPLE JACKET 3' TAPE SPACING, <br />STRAP 1' WIDE FILAMENT TAPE <br />TOO NNN WHIM SCOTCH BRAND tMB <br />ELKS <br />7 .R APPROVED E UAL <br />YARD <br />LOCATION PLAN <br />F� _. <br />Of DKA ; sMxadM <br />�roar aHa 1Nr �� I <br />Ndl <br />METER BOX AND SERVICE SIZE TABLE <br />METER <br />SIZE <br />PIPE �'y E <br />CORPORATION <br />STOP <br />CURB <br />STOP <br />DIMENSION <br />ARNORCAST 1W DTHAENGTHxDEPrH <br />COV RATED <br />MM. (NS) <br />5/8% <br />3/4'. <br />1 1/2' <br />(ID -1.241 <br />yy EE11yyEERR <br />H -15023N <br />8 242'8.5N <br />A600 1429 12' x 18' x 12' <br />A600 1428-H7 NO <br />- <br />1' <br />(OD -1.625 <br />.,,Q,..r.4�........ (.'t'. <br />1 1/2' <br />ID -i 828 <br />MUELLER <br />H -15028N <br />A1p �Fp <br />H-14288 W/ <br />�'�s <br />1840P�C1Li2 17' x 30' x 12' <br />A600 1613-H7 NO <br />2' <br />(oD-i.125 <br />Inc <br />_'! "':' <br />(*INSTALL <br />6' PORTLAND CEMENT CONCRETE SUB UNDERNEATH FOR SUPPORT.) <br />NOTE <br />1. ALL SERVICES TO BE WET TAP AT EXISTING AWNS FOR NEW MAIN% NEW SERVICES CAN BE DRY TAP OR AS <br />DIRECTED BY CITY ENGINEER. <br />2. USE j10 AWG COPPERHEAD SOLD PURPLE TRACER WIRE IN A SINGLE LENGTH OF WIRE WITH INSULATION INTACT. <br />LOCATOR WIRE MUST BE CONNECTED 70 WATERMAIN LOCATOR WIRE USING BRASS WIRE SPLIT NUTS TO PROVIDE A <br />COMPLETE CIRCUIT. COAT CUT END OF WIRE WTTH SCOTCHKOTE ELECTRICAL COATING OR EQUAL <br />3. CENTER METER BOX OVER METER TO GRAM <br />4. INSTALL METER BOX w/ FLEXNEr ANI READING LIDS (PROBE HOLE) <br />5. REMOVE AND REPLACE EXISTING WATER METER BOX TO NEW LOCATION AS INDICATED ON THE LOCATION PLAN ON <br />THIS SHEET. REPLACE SERVICE PIPE AND YARD PIPING WITH NEW PE PIPE WITH MIN. PIPE DWNETEN AS SHOWN <br />ON THE TABLE ABOVE, <br />6. STAMP 'RW' ON TOP OF CURB IN FRONT OF METER BOX. <br />7. PAINT INSIDE OF BOX PURPLE (PANTONE 512). <br />e. ALL BENDS IN PLASnC PIPE SHALL HAVE A MINIMUM (AMUS OF 30 PIPE DIAMETERS. <br />9. PROVIDE ALL TUBING AND COMPRESSION UNIONS IN COPPER TUBE SIZING (C -T -S). <br />10. FOR SMALL SERVICE CONNECTIONS TO EXISTING SERVICES PROVIDE STRAIGHr METER SWNEt NUT AND UNIONS <br />AND CONNECT TO EXISTING YARD PIPING. NOT TO SCALE <br />DRAFT CITY OF REDWOOD CITY <br />ENGINEERING AND CONSTRUCTION <br />DETAIL 11-112" AND 2" RECYCLED WATER RW -3A <br />DATE- 03/10/17 I SERVICE TO HDPE MAIN SHT 1 OF 1 <br />REV: 04-06-17 PR <br />Page 23 of 29 <br />ATTY/AGR.20W.073/Stanford - Subdivision Improvement Agreement <br />