My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
AgdaPkt 2017-07-24 Closed and Joint SA FPA
RedwoodCity
>
City Clerk
>
Agenda Packets
>
2010-2019
>
2017
>
AgdaPkt 2017-07-24 Closed and Joint SA FPA
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/21/2017 12:52:47 PM
Creation date
7/20/2017 4:36:59 PM
Metadata
Fields
Template:
CC Index
CC Index - Document Type
Agenda Packet
Meeting Type
Joint
Agency Type
City Council and Successor Agency and Public Financing Authority
Date
7/24/2017
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
500
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
6.1.E. - Page 28 <br />g. Peristaltic pump <br />i. Positive displacement, peristaltic type tubing pump with brushless variable <br />speed motor, non -spring loaded roller assembly in the pump head, integral tube <br />failure detection system, and flexible tubing with attached connection fittings. <br />ii. Specifications: <br />1. Repeatability: +/- 1 percent <br />2. Accuracy: +/- 1 percent <br />iii. Pump is equipped with stop/start, operating mode selection, auto priming, and <br />reverse direction. <br />h. Requirements for total/free chlorine sensor: <br />i. Type 3 -electrode amperometric membrane -type sensor <br />ii. Measuring range of 0-20 mg/L <br />iii. Resolution of 0.01 mg/L <br />iv. Response time (T90) of approximately 2 minutes <br />v. Interferences: Chlorine dioxide (C102) and ozone (03) <br />vi. Calibration: slope calibration achieved at the device by DPD -4 method <br />(DPDI+DPD3) analytical determination. Zero -point adjustments not <br />necessary. <br />i. Requirements for DH sensor: <br />i. Combined 2 -electrode type pH probe <br />ii. Measuring range of 0-14 <br />iii. Resolution of 0.01 <br />iv. Span: 97% of theoretical or higher <br />v. Response Time (T95): 1 second <br />vi. Offset: +/- 0.20 pH <br />vii. Calibration: 3 -point calibration with reference solutions <br />j. Requirements for ORP sensor: <br />i. Combined 2 -electrode type ORP probe with double junction <br />ii. Measuring range of +/- 1000 mV <br />iii. Resolution of +/- 0.5 mV <br />iv. Calibration: 1 -point or 2 -point calibration that can be performed with 1 or 2 <br />reference solutions <br />k. SCADA compatible <br />i. 8 analog output (4-20 mA or 0-10 V) <br />ii. 8 digital relay <br />iii. Modbus TCP or serial RS -485 communication <br />1. Equipped with adjustable pressure regulator for flow control and a flow switch for <br />flow verification <br />m. Enclosure must be made of weatherproof material and parts <br />C. Chlorine Chemical Feed System <br />a. Skid -mounted chemical metering pump, chemical container, chemical level sensors, <br />enclosure for pump and chemical containers, injection nozzles, tubing, and spill <br />containment storage <br />NOTICE INVITING BIDS <br />2016-2017 RECYCLED WATER TANK WATER QUALITY CONTROL SYSTEM 11 of 16 <br />
The URL can be used to link to this page
Your browser does not support the video tag.