My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
Res99 13692
RedwoodCity
>
City Clerk
>
Resolutions
>
City Council
>
1990-1999
>
1999
>
Res99 13692
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/5/2005 2:58:51 PM
Creation date
10/7/2002 10:42:23 AM
Metadata
Fields
Template:
CC Index
CC Index - Document Type
Resolution
Agency Type
City Council
Date
7/26/1999
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
20
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
ATTACHMENT <br /> <br />Inspection Report 303 Heller, 309 Heller, 418 Cassia <br /> <br />Inspection Conducted by David Roberson Building Inspector, Gary Lepori Building Inspector, Valerie <br />Schwarz Building Inspector, Luis Curincita Community Service Officer, Bob Hail Fire Prevention Officer, <br />and Lindsey Gipe San Maten County Health Officer, on June 8, 1999. <br /> <br />The property owner's representative, Orville Riggle, was present for inspection. <br /> <br />The following items require repairs/corrections for these buildings to be considered habitable, rentable <br />dwellings: <br /> <br />Exterior of Buildings <br /> numerous engine parts, car parts, automobile parts, lying on ground, visible from public view [must be <br /> removed] <br /> two (2) engine hoists and other evidence of tenant/occupant working on vehicles other that his own <br /> registered vehicles [must be removed] <br /> three (3) inoperative vehicles visible from public view [must be removed] <br /> garbage, debris, junk, old building materials lying on ground, visible fi.om public view [must be <br /> removed] <br /> oil, automobile fluids, other hazardous automobile liquids spilled over asphalt driveway, concrete <br /> walk-ways, dirt/ground [ must be properly removed and disposed of by a qualified hazardous materials <br /> contractor] <br /> two (2) of the garages were being used as sleeping rooms during the inspection with illegal and <br /> improper wiring methods including extension cords and hazardous light methods (candles) [ must be <br /> eliminated] <br /> rn one (1) trailer in one of the back yards was being used as a sleeping room during the inspection with <br /> gaTardous light methods (candles) [ must be removed] <br /> ~ one (1) tenant recycles old copper conductors (large pile vis.lc fi-om public way) [ must be removed] <br /> <br /> Violations Common to All Three (3) Dwellings/Addresses <br /> significantly failed foundation iystems including severely sloping floors, racked door and window <br /> fi.ames all primarily due to inadequate surface drainage at exterior of buildings, inadequate gutter and <br /> downspout system, and negative grading adjacent to the building exterior [foundations would require <br /> significant modifications including raising buildings, removal of existing failed concrete perimeter <br /> foundations, and replacement of said concrete perimeter foundations] <br /> numerous broken and inoperable bedroom egress windows and interior room windows due to racking <br /> of window fi.ames as a result of building movement/settlement [repair and replacement of windows <br /> would not be prudent until foundation systems were repaired to help prevent future <br /> movement/settlement and future racking of window frames] <br /> rn significant cracking of interior walls above door and window frames [repair of said cracks would not <br /> be prudent until foundation systems were repaired to help prevent future movement] <br /> all three (3) wall heaters are significantly deteriorating (all at end of useful life); one (1) tenant has <br /> electric resistance cord and plug connected type heater; one (1) tenant has placed combustible couch <br /> against face of heater due to lack of access in living area; [replacement of all heaters is required to <br /> meet habitable space heating requirements] <br /> ~ numerous missing coverplates with exposed "live" electrical conductors are visible in each unit <br /> [replacement of all receptacle outlet, switch outlet, and lighting outlet coverplates] <br /> no visible working smoke detectors are installed [install working smoke detectors in all sleeping rooms <br /> and hallways leading to sleeping rooms] <br /> I <br /> <br /> EXHIBIT <br /> <br /> 13692 <br /> <br /> <br />
The URL can be used to link to this page
Your browser does not support the video tag.