Laserfiche WebLink
significantly deteriorating bathroom floors, walls, and enclosures due to excessive moisture inmasion <br /> outside of bathroom tab/shower enclosures [contact a competent licensed pest control operator to <br /> conduct physical inspection of entirety of said structures including water areas like the bathrooms, <br /> exteriors and kitchens to determine how much water and dry rot damaged wood and building materials <br /> would be required to be removed and replaced] <br /> linoleum flooring damaged, deteriorated in all of the units [contact a competent licensed pest control <br /> operator to conduct physical inspection of entirety of said to determine how much flooring would be <br /> required to be removed and replaced] <br /> water heaters are all at end of useful life; all have significantly failed vent connectors, and venting <br /> systems which allow products of combustion into the living areas [carbon monoxide and other <br /> combustion products are probably being released into these units in undetermined levels; removal and <br /> replacement of all three (3) water heating systems including venting systems is required for these <br /> dwellings to be considered habitable] <br />tn all three (3) water heaters are not seismically anchored to structure [add two (2) s~raps to each water <br /> heater as required by Uniform Plumbing Code] <br />rn general state of disrepair of interior of units due to owner not correcting repairable items <br /> <br />Additional Violations at 309 Heller Dwellling <br /> holes in plaster walls in numerous locations [patch/repair holes with plaster repair] <br /> improper unsafe light fixtures being energized by extension cords [remove and properly rewire with <br /> code complying wiring method] <br />rn water heater missing gas and water shut-off valves [install valves as required by Uniform Plumbing <br /> Code] <br />ca water heater supply piping significantly deteriorating, resting, and leaking [remove and replace <br /> deteriorated piping] <br /> significant grease accumulation above kitchen cooktop at cabinets, ceilings, and walls is an extreme <br /> fire hazard [clean grease and install proper mechanical ventilation and make kitchen window operable]- <br /> <br />Additional Violations at 303 Heller Dwelling <br />tn significant grease accumulation above kitchen coo~op at cabinets, ceilings, and walls is an extreme <br /> fire hazard [clean grease and install proper mechanical ventilation] <br /> ca bathroom tab-shower fixtares leaking [repair leaking fixtures] <br /> <br /> Additional Violations at 418 Cassia Dwelling <br /> roof system significantly failed, rotted and sagging roof rarer% and staining on interior ceilings <br /> [remove and repair roof system] <br /> bathroom tab-shower and sink fixtares leaking [repair leaking fixtures] <br /> bathroom toilet loose, rotted flooring at base [repair leaking fixtures and rotted flooring] <br /> no hot water at kitchen sink due to significantly deteriorated piping [remove and replace deteriorated <br /> piping] <br /> Cl open sewer at back yard/side of house [properly cap sewer line] <br /> <br /> 2 <br /> <br /> 13691 <br /> <br /> <br />