ATTACHMENT <br /> <br />Inspection Report 303 Heller, 309 Heller, 418 Cassia <br /> <br />Inspection Conducted by David Roberson Building Inspector, Gavj Lepori Building Inspector, Valerie <br />Schwarz Building Inspector, Luis Curincita Community Service Officer, Bob Hall Fire Prevention Officer, <br />and Lindsey Gipe San Mateo County Health Officer, on June $, 1999. <br /> <br />The property owner's representative, Orville Riggle, was present for inspection. <br /> <br />The following items require repairs/corrections for these buildings to be considered habitable, rentable <br />dwellings: <br /> <br />Exterior of Buildings <br />o numerous engine parts, car parts, automobile parts, lying on ground, visible from public view [must be <br /> removed] <br /> two (2) engine hoists and other evidence of tenant/occupant working on vehicles other that his own <br /> registered vehicles [must be removed] <br /> three (3) inoperative vehicles visible from public view [must be removed] <br /> garbage, debris, junk, old building materials lying on ground, visible from public view [must be <br /> removed] <br />o oil, automobile fluids, other bsTardous automobile liquids spilled over asphalt driveway, concrete <br /> walkways, dirt/ground [ must be properly removed and disposed of by a qualified hazardous materials <br /> contractor] <br /> two (2) of the garages were being used as sleeping rooms during the inspection with illegal and <br /> improper wiring methods including extension cords and baTardous light methods (candles) [ must be <br /> eliminated] <br />n one (1) trailer in one of the back yards was being used as a sleeping room during the inspection with <br /> hazardous light methods (candles) [ must be removed] <br /> o one (1) tenant recycles old copper conductors (large pile visible from public way) [ must be removed] <br /> <br /> Violations Common to All Three (3) Dwellings/Addresses <br /> significantly failed foundation systems including severely sloping floors, racked door and window <br /> frames all primarily due to inadequate surface drainage at exterior of buildings, inadequate gutter and <br /> downspout system, and negative grading adjacent to the building exterior [foundations would require <br /> significant modifications including raising buildings, removal of existing failed concrete perimeter <br /> foundations, and replacement of said concrete perimeter foundations] <br /> numerous broken and inoperable bedroom egress windows and interior room windows due to racking <br /> of window frames as a result of building movement/settlement [repair and replacement of windows <br /> would not be prudent until foundation systems were repaired to help prevent future <br /> movement/settlement and future racking of window frames] <br /> significant cracking of interior walls above door and window frames [repair of said cracks would not <br /> be prudent until foundation systems were repaired to help prevent future movement] <br /> all three (3) wall heaters ere significantly deteriorating (all at end of useful life); one (1) tenant has <br /> electric resistance cord and plug connected type beater; one (1) tenant has placed combustible couch <br /> against face of heater due to lack of access in living area; [replacement of all heaters is required to <br /> meet habitable space heating requirements] <br /> O numerous missing coverplatas with exposed "live" electrical conductors are visible in each unit <br /> [replacement of all receptacle outlet, switch outlet, and lighting outlet coverplates] <br /> <br /> O no visible working smoke detectors are installed [install working smoke detectors in all sleeping rooms <br /> and hallways leading to sleeping rooms] <br /> <br /> 13690 <br /> <br /> EXHIBIT <br /> <br /> <br />