Laserfiche WebLink
<br />bathtub, shower, or water closet, installed individually <br />or as a single group in residences, apartments, hotels, <br />hospitals, or rest rooms in commercial establishments <br />where the fixtures are in:tended solely for the use of <br />the occupants or family. <br />" · Condensate Waste. Waste water caused by the <br />formation of moisture on the outside of coils or other <br />surfaces. <br />"'First Floor. The first floor is the ground <br />floor, or the slab floor above the garage, basement, <br />or crawl space.' <br />"(b) Chapter 1 of the Plumbing Code is amended by <br />changing the definitions of 'Horizontal Pipe' and 'Vertical <br />Pipe' to read as follows: <br />"'Horizontal Pipe. An horizontal pipe is any <br />pipe or fitting which is installed in an horizontal <br />position or which makes an angle of more than 72 degrees <br />with the vertical. <br />"'Vertical Pipe.. A vertical pipe is any pipe or <br />fitting which is installed in a vertical position, or <br />which makes an angle of not more than 72 degrees with <br />the vertical. I <br />"section 24.20 Subsection (k) of Section 201 is not <br />adopted and shall not be a part of the,paurnning.Code. <br />"Section 24.21 Section 203 of the Plumbing Code is <br />amended to read as follows: <br />II 'Section 203 (a) Copper tube for underground <br />drainage and vent piping shall have a weight of not <br />less than that of copper water tube Type L. <br />"' (b) Copper tube for above ground drain~ge and <br /> <br />-7- <br />