Laserfiche WebLink
<br />PLACE ARROW INDICATING NORTH <br />'IRECTION RELATIVE TO CROSSING <br /> <br /> <br />FORM DR- 0404- B <br />REV. 5-15-98 <br /> <br />ENCASED NON-FLAMMABLE <br />PIPELINE CROSSING <br /> <br />NO SCALE <br /> <br />NOTE: ALL AVAILABLE DIMENSIONS MUST BE <br />FILLED IN TO PROCESS TH[S APPLICATION. <br />@ <br /> <br />~W1l>lj1 <br /> <br />TO (ITy <br />( NEARES r R. R. TOWN I <br /> <br />\."~h <br />- I~f H. <br />(SEE NOTE 3 B 5) <br /> <br /> <br />r FT. <br />50 I F-r.- <br />(SEE NOTE 3 B 5) <br /> <br />o . 0 <br /> <br />bWlTctI7N6- fril8j ~ <br />( OESCR I BE F I XED OBJEC T) <br />(SEE NOTE S) <br /> <br />(OISTANCE ALONG TRACK FROM SECTION LINE CROSSING' <br /> <br />'310$' H. <br /> <br />(NOTE: THIS DIMENSION REOUIRED IN ALL CASES. <br />AT LOCATIONS NOT USING SECTIONS, OISTANCE <br />TO A LEGAL SURVEY LINE IS REOUIRED) <br /> <br />@ <br /> <br />RR'S R/W <br /> <br />l _~JT. 'l~ .Q..FT. ...'. <br />I <br /> , <br />r"'" "" . , I <br />fl (See Note 2) <br />I ROADBED <br /> <br />~FT. <br /> <br /> <br />SEAL CASING <br />) <br /> <br />@ <br /> <br />/ <br />/ <br /> <br />L CARRIER PIPE <br /> <br />" <br />" <br /> <br />"-l",,J <br /> <br />!U..n. " <br /> <br />/ <br />/ <br />/ <br /> <br />"~I <br />I <br /> <br />S FT. <br /> <br />l.(l H. <br /> <br />fjl.{ F r. <br />8''f FT. <br />NOTES: (CASING LENGTH IIHEN MEASURED ALONG PIPELlNL) <br />II ALL HORIZONTAL DISTANCES TO BE MEASURED AT RIGHT ANGlES FROM'l OF TRAGK. <br />21 CASING TO EXTEI\O BEYOND THE t. OF TRACK AT RIGHT ANGLES THE GREATER OF 20. 20 FT., OR 30 FT.. <br />ANI BEYONO LIIIIT OF RAllROAll RIGHT-Of-WAY IF NECESSARY TO PROVIDE PROPER lENGTH OUTSIDE OF TRACK. <br />3. IIINI_ Of 50' FROM THE ENO OF ANY RAilROAD BRIDGE. to Of ANY CUlVERT, OR FROM ANY SWITCHING AREA. <br />~. SIGNAL REPRE5ENrATlvE IoIJST BE PRESENT DUliNG INSTALLATION IF RAILROAD SIGNAlS ARE IN THE VICINITY OF CROSSING. <br />S. AllOWABLE FIXED OllJECTS INClUOE: 8I.CKWALlS OF BRIDGES; 'l OF ROAD CROSSINGS 8 OVERHEAD VIADUCTS I GIVE ROAD NAllEI, OR CUl.VERTS. <br />61 CASING AND CARRIER PIPE IoIJST BE PlACED A IIINI_ OF 2 FEET BElOW THE EXISTING FIBER OPTIC CABLE. ANY EXCAVATION REOUIRED WITHIN <br />5 FEET OF THE EXISTING FIBER OPTIC CABLE IolJST BE 1IA1\O DIIGo <br />A) [S PIPELINE CROSSING WITHIN DEDICATED STREET ?____YES;____NO; <br />Bl IF YES, NAME OF STREET ct\esJ'\feA-~ M,,,.e' <br />01 D[STRIBUTlON LINE 7" OR TRANSMISS[ON LINE <br />Cl CARRIER PIPE: <br />COMMOD [TY TO BE CONVEYED /<eGtftlM Vb vJ l}uf2- <br />OPERATING PRESSURE 60 PSI." <br />WALL TH I CKNESS . H> >' :0 I AMETER 1~.Qr ; MA TER I AL f' ~ c.. <br />EI CASING PIPE. I " rir" <br />WALL THICKNESS 7'16 ;DIAMETER'l.J..lt.) :MATERIAL STefL ; <br />NOTE :CASING MUST HAVE 2" CLEARANCE BETWEEN GREATEST <br />OUTSIDE D[AMETER OF CARR[ER PIPE AND INTERIOR DIAMETER OF <br />CASING PIPE. WHEN FURNISHING DIMENSIONS, GIVE OUTSIDE OF <br />CARRIER PIPE AND INSIDE OF CASING PIPE. <br />F) METHOD 05 INSTALLING CASING PIPE UNDER TRACKISI: <br />~DRY BORE AND JACK (WET BORE NOT PERMITTEDI ; <br />- TUNNEL: OTHER RR FILE NO <br />GI WILL CONSTRUCTION BE BY AN OUTSIDE CONTRACTOR?~YES:----NO; . <br />HI DISTANCE FROM CENTER LINE OF TRACK TO NEAR FACE OF BORING AND <br />JACKING PITS WHEN MEASURED AT RIGHT ANGLES TO TRACK ~2' <br />I) APPLICANT HAS CONTACTED 1-800-336-9193, (~' 1I1~) <br />U. P. COMMUNICAT[ON DEPARTMENT, AND HAS DETERMINED FIBER <br />OPTIC CABLE_DOES ;~DOES NOT: EXIST IN VICINITY OF <br />WORK TO BE PERFORMED. TICKET NO. z....'1- 04 Q 3 00 "I <br /> <br />RR'S R/W <br /> <br />I}". <br /> <br />poe.T ~F- <br />fl.\?.AN<> ~ CITy <br />TO f <br />(NEAREST R. R. TOWN) <br /> <br />.... <br />'" <br />a <br />,,0<'- <br />""" <br />~ <br />:i <br /> <br />~H. <br /> <br />I <br /> <br />~ <br />ex: <br />'" <br />0: <br />ex: <br /> <br />*' o~ ~I\<:t::.. ~UNN-IO <br /> <br />STEEL CASING WALL <br />THICKNESS CHART <br />MINIMUM OIAMETER OF <br />THICKNESS CASING PIPE <br />. 2500" I/~" 12" OR LESS <br />. 3125" 51 16" OVER 12"- 18" <br />. 3750" 3/8" OVER 18"- 22" <br />.4375" 7/16" OVER 22"-28" <br />.5000" '/2" OVER 28"- 34" <br />.5625" 91 16" OVER 34"- 42" <br />.6250" 5/8" OVER 42"- 48" <br />OVER 48" MUS7 BE <br />APPROVED BY R. R. CO. <br />NOTE: THIS CHART IS ONLY <br />FOR SMOOTH STEEL CASING <br />PIPES WITH MINIMUM YIELD <br />STRENGTH OF 35,000 PS I. <br /> <br />FORMULA TO FIGURE CASING <br />LENGTH WITH ANGLE OF <br />CROSSING OTHER THAN 900 <br /> <br />.....!L- <br />a, SIN <br /> <br /> <br />B <br />MIN. DIST. <br />(HOTE 2) <br /> <br />EXHIBIT " A " <br /> <br />(FOR RA [LAGAO USE at<<. YJ <br /> <br />UNION PACIFIC RAILROAD CO. <br />It.JW...J H.,"'- I..J. 1.,..,( <br /> <br />M. P 1.,." E. S. 11..'l~ <br />ENCASED PI,&,...~ CROSS I NG AT <br />1t..J. ""...\ < :t., S... ~+... c A <br /> <br />(NEARESr CCTYI I COtMTY) ISUrE' <br /> <br />C ,'11 .f 1-tJ__..J. <br /> <br />C APPUCANTJ <br />1.",,-&,. 4~ <br /> <br />WAR N I N G <br /> <br />I SUBOIVIS[ONI <br /> <br />Ltty <br />DA TE ~."..7 <br /> <br />IN All OCCASIONS, II. P. CDIoM.JNICAflONS <br />DEPARTMENT IoIJSr BE CONTACTED IN ADVANCE <br />OF ANY WORK TO DETERIIINE EXISTENCE AND <br />lOCArIDN OF FIBER OPTIC CAlllE. <br />PHONE: 1-800-336-'3193 <br />