Laserfiche WebLink
d. Work using the public right-of-way for any fixed structure (awnings, roof <br />overhangs, fixed planters, etc.). Insurance, meeting the City's standards, is <br />required. This permit will be recorded against the property. <br />29. Sewer Capacity - Prior to encroachment permit issuance, submit to the City, and obtain <br />approval of, an evaluation and report prepared by a licensed engineer demonstrating that <br />the existing sewer mains have sufficient capacity for the project. The study shall consider <br />existing, project, other approved projects, and applications currently under review in <br />determining the needed capacity. If the existing sewer main is less than 6" in size, or is in <br />any other way not sufficient as determined by the City Engineer, applicant shall, as part <br />of the Project, construct and install new sewer mains sufficient to meet such <br />requirements, in accordance with the City's Engineering standards and as directed by the <br />City Engineer to the City Engineer's satisfaction. [SDR] [ENGINEERING] <br />30. Peak Wet Weather Flow Capacity - Redwood City has exceeded its Peak Wet Weather <br />Flow (PWWF) capacity in the past. A methodology to reduce inflow and infiltration (I/I) <br />by pipe replacement was determined. The applicant shall reduce (I/I) to offset increased <br />sewer demand from the project by replacing aged sewer mains or pay an equivalent in - <br />lieu fee. The length of pipe replacement required or the amount of fee will be based on <br />the project's sewage generation projection (Attachment L of the City's Engineering <br />Standards). For parcels within Redwood City but connecting to County owned and <br />maintained sewer, an I/I in -lieu fee may be collected by Redwood City if the County does <br />not require main replacement or collect and in -lieu fee.. [COA] [ENGINEERING] <br />31. Sewer Lateral Limit - The project is limited to one sewer lateral per parcel. <br />[COA] [ENGINEERING] <br />32. Sewer Lateral Size for Commercial Development- For new or remodeled commercial <br />buildings, sewer laterals less than 4" shall be upgraded to a minimum 6" size. [SDR] <br />[ENGINEERING] <br />33. Water Mains - Prior to encroachment permit issuance, submit to City, and obtain <br />approval of, an evaluation and report, prepared by a licensed engineer, in conformance <br />with the City's Engineering Standards, demonstrating that the proposed water main <br />meets the domestic and fire flow requirements in accordance with City Code Section <br />38.26 and the International Fire Code. If the existing water main is less than 6" in size, or <br />is in any other way not sufficient as determined by the City Engineer, applicant shall, as <br />part of the Project, construct and install new water mains sufficient to meet such <br />requirements, in accordance with the City's Engineering Standards and as directed by the <br />City Engineer. New water mains shall be 8" minimum in size and extend across the entire <br />property frontage, from the nearest point of connection to an existing 6" or larger water <br />main. [SDR] [ENGINEERING] <br />34. Water Meters - The project is limited to one "master" water meter for domestic water <br />service. Any metering for individual units must be accomplished by private sub -meters <br />within the property. [COA] [ENGINEERING] <br />ATTY/RESO.0016/PC RESO APPROVING PERMITS FOR 610 WALNUT STREET <br />REV: 02-20-19 PR <br />Page 10 of 16 <br />