My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
Res18 15665
RedwoodCity
>
City Clerk
>
Resolutions
>
City Council
>
Working
>
2010-2019
>
Res18 15665
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/11/2019 7:59:29 AM
Creation date
10/11/2019 7:59:25 AM
Metadata
Fields
Template:
CC Index
CC Index - Document Type
Resolution
Meeting Type
Joint
Agency Type
City Council and Successor Agency and Public Financing Authority
Date
5/21/2018
Description
A RESOLUTION OF THE CITY COUNCIL OF THE CITY OF REDWOOD CITY DENYING THE APPEAL AND APPROVING A PLANNED COMMUNITY PERMIT, DENSITY BONUS INCLUIDNG A HEIGHT CONCESSION, AND AFFORDABLE HOUSING PLAN FOR 353 MAIN STREET PURSUANT TO THE CITY OF REDWOOD CITY'S NORTH MAIN STREET PRECISE PLAN, AND FINDING THAT SAID APPROVALS ARE EXEMPT FROM THE REQUIREMENTS OF THE CALIFORNIA ENVIRONMENTAL QUALITY ACT
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
30
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
35. Encroachment Permits — Obtain an Encroachment Permit from the Engineering <br />and Transportation Division for work listed below. This permit shall be obtained <br />prior to the commencement of construction of the road, utilities, or any site <br />improvements. [SDRI[ENGINEERING] <br />a. Work in the City public right-of-way, easements or property in which the <br />City holds an interest. <br />b. Work requiring a grading permit. Grading permits require a Plot and <br />Finished Grading Plan prepared by a California -registered Civil Engineer. <br />c. Work requiring on-site shoring which affects the public right of way <br />d. Work using the public right-of-way for any fixed structure (awnings, <br />roof overhangs, fixed planters, etc.). Insurance, meeting the City's <br />standards, is required. This permit will be recorded against the property. <br />36. Peak Wet Weather Flow Capacity — Redwood City has exceeded its Peak <br />Wet Weather Flow (PWWF) capacity in the past. A methodology to reduce <br />inflow and infiltration (1/1) by pipe replacement was determined. The applicant <br />shall reduce (1/1) to offset increased sewer demand from the project by replacing <br />aged sewer mains or pay an equivalent in -lieu fee. The length of pipe <br />replacement required or the amount of fee will be based on the project's sewage <br />generation projection (Attachment L of the City's Engineering Standards). For <br />parcels within Redwood City but connecting to County owned and maintained <br />sewer, an 1/1 in -lieu fee may be collected by Redwood City if the County does <br />not require main replacement or collect and in -lieu fee. [COA][ENGINEERING] <br />37. Sewer Lateral Limit — The project is limited to one sewer lateral per parcel. <br />[COA][ENGINEERING] <br />38. Sewer Lateral Size for Commercial Development - For new or remodeled <br />commercial buildings, sewer laterals less than 4" shall be upgraded to a <br />minimum 6" size. [SDR] [ENGINEERING] <br />39. Water Mains — Prior to encroachment permit issuance, submit to City, and <br />obtain approval of, an evaluation and report, prepared by a licensed <br />engineer, in conformance with the City's Engineering Standards, demonstrating <br />that the proposed water main meets the domestic and fire flow requirements in <br />accordance with City Code Section 38.26 and the International Fire Code. If the <br />existing water main is less than 6" in size, or is in any other way not sufficient as <br />determined by the City Engineer, applicant shall, as part of the Project, construct <br />and install new water mains sufficient to meet such requirements, in accordance <br />with the City's Engineering Standards and as directed by the City Engineer. New <br />water mains shall be 8" minimum in size and extend across the entire property <br />frontage, from the nearest point of connection to an existing 6" or larger water <br />main. [SDR][ENGINEER[ NG] <br />ATTY/RESO.0041/CC RESO DENYING THE APPEAL FOR 353 MAIN STREET <br />REV: 05-14-18 PR <br />Page 15 of 29 <br />RESO NO. 15665 <br />MUFF NO. 603 <br />
The URL can be used to link to this page
Your browser does not support the video tag.