My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
Ord 2402
RedwoodCity
>
City Clerk
>
Resolutions
>
City Council
>
Working
>
Ordinances
>
2010-2019
>
Ord 2402
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/11/2019 2:49:30 PM
Creation date
10/11/2019 2:49:29 PM
Metadata
Fields
Template:
CC Index
CC Index - Document Type
Ordinance
Meeting Type
Regular
Agency Type
City Council
Date
1/13/2014
Description
AN ORDINANCE OF THE CITY OF REDWOOD CITY REPEALING ARTICLE II OF CHAPTER 12 OF THE REDWOOD CITY MUNICIPAL; AND ADDING A NEW ARTICLE II TO CHAPTER 12 OF THE REDWOOD CITY MUNICIPAL CODE ADOPTING BY REFERENCE THE "CALIFORNIA FIRE CODE, 2013 EDITION, PUBLISHED BY THE CALIFORNIA BUILDING STANDARDS COMMISSION AND BASED ON THE 2012 EDITION OF THE INTERNATIONAL FIRE CODE
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
10
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
01/13/2014 <br /> and structures. The requirements of Section 907.2 are applicable to new buildings and <br /> structures. The requirements of Section 907.9 are applicable to existing buildings and <br /> structures. Multiple fire alarm systems within single protected premises are not <br /> permitted, unless prior written approval is obtained by the Fire Code Official. <br /> Sec. 12.23. SECTION 907.2.13.2. ADDED. <br /> Section 907.2.13.2. is hereby added to the Fire Code to read as follows: <br /> 907.2.13.2. Multistoried, High Rise Safety Requirements. <br /> (a) Firefighters Communications Systems: When required by the Fire Code <br /> Official, buildings six (6) or more stories in height, firefighter's communication <br /> systems shall be installed in accordance with the following requirements: <br /> (i) One access jack shall be provided at each stairwell landing and finro (2) <br /> access jacks shall be provided in a lobby area of the building in plain view of <br /> elevator doors, and in any event at locations and according to specifications <br /> subject to the approval of the fire code official. <br /> (ii) One telephone set shall be provided at each floor of the building; provided, <br /> that such telephone sets shall be located in the lobby area at a location and <br /> according to specifications subject to the approval of the fire code official. <br /> (iii) One additional telephone set shall be provided with not less than five <br /> hundred feet (500') of telephone cord and shall be maintained on a roller device <br /> providing convenient portability. Said telephone set shall likewise be maintained <br /> at a location and according to specifications approved by the fire code official. <br /> (b) Emergency Planning and Information: Buildings and occupancy groups <br /> specified in Title 19 of the California Code of Regulations, Section 3.09, and <br /> buildings with four (4) or more stories in height shall have posted a floor plan sign <br /> which shall provide emergency procedures at every stairway landing, elevator <br /> landing, and immediately inside all public entrances to the building. Information <br /> contained in the floor plan signs shall include, but shall not be limited to, the <br /> following: <br /> 1. Location of exits and fire alarm initiating stations; <br /> 2. Description of fire alarm sounds and appearance; <br /> 3. Fire Department emergency telephone number "911"; <br /> 4. Prohibition of the use of elevators during emergencies; <br /> 5. Instructions to be followed by ambulatory, nonambulatory, and disabled <br /> persons in the event of an emergency; <br /> 6. Notation `you are here' or other readily understandable marking specifying <br /> the location on the floor plan sign. <br /> Floor plan signs shall be printed in a nondecorative lettering which shall not be less <br /> than three-sixteenths of an inch (3/16") in height and shall provide a sharp contrast <br /> ATTY/ORD.397/FIRE CODE ORDINANCE ORD.#2402 <br /> REV:11-20-13 JS FORMERLY MUFF#305 <br /> Page 6 of 9 <br />
The URL can be used to link to this page
Your browser does not support the video tag.