Laserfiche WebLink
piping system for the replenishment of portable life sustaining air equipment <br /> carried by fire department, rescue, and other personnel in the performance <br /> of their duties. Location and specifications o! access stations to, and the <br /> installation of, such rescue air replenishment systems shall be made in <br /> accordance with the requirements of the Fire Chief. <br /> <br /> (b) Firefighters Communication Systems: I~n buildings six (6) or more <br /> stories in height, firefighters communication systems shall be installed in <br /> accordance with the following requirements: <br /> <br /> (i) One access jack shall be provided at each stairwell landing and two <br /> (2) access jacks shall be provided in a lobby area of the building in plain <br /> view of elevator doors, and in any event at locations and according to <br /> specifications subject to the approval of the Chief of the Bureau of Fire <br /> Prevention. <br /> <br /> (ii) One telephone set shall be provided at each floor of the building; <br /> provided, that such telephone sets shall be located in the lobby area at a <br /> location and according to specifications subject to the approval of the <br /> Chief of the Bureau of Fire Prevention. <br /> <br /> (iii) One additional telephone set shall be' provided with not less than <br /> five hundred feet (500') of telephone cord and shall be maintained on a <br /> roller device providing convenient portability. Said telephone set shall <br /> likewise be maintained at a location and according to specifications <br /> approved by the Chief of Bureau of Fire PreVention. <br /> <br /> (c) Emergency Planning and Information: Buildings and occupancy groups <br /> specified in Title 19 of the California Code of Regulations, Section 3.09, and <br /> buildings with four (4) or more stories in heig~ht shall have posted a floor <br /> plan sign which shall provide emergency procedures at every stairway <br /> landing, elevator landing, and immediately inside all public entrances to the <br /> building. Information contained in the floor plan signs shall include, but <br /> shall not be limited to, the following: <br /> <br /> 1. Location of exits and fire alarm initiating stations; <br /> <br /> 2. Description of fire alarm sounds and appearance; <br /> <br /> 3. Fire Department emergency telephone number "911"; <br /> <br /> 4. Prohibition of the use of elevators during emergencies; <br /> <br /> 5. Instructions to be followed by ambulatory, nonambulatory, and <br /> disabled persons in the event of an emergehcy; <br /> <br />Ord-069a 5 2166 <br />FlshlshlRClCouncil <br />05/25/99R;O6101199;O6/O7/99R <br />FX$/DE$:rg <br /> <br /> <br />