Laserfiche WebLink
<br />" , (3) Ordinance No. 1130 (Zoning) . <br />'" (b) The ordinance or Code provisions of this section <br />shall not be construed to preclude the issuance of, a <br />building permit when there are previously or concur- <br />rently issued permits for improvements which would <br />eliminate any noncompliance with the abovementioned <br />ordinances. All such necessary improvements shall <br />be constructed concurrently with the work being done <br />on the structure for which the building permit is issued.'" <br />"Section 9.44 Section 309 is hereby added to the Building <br />Code to read as follows: <br />"'Section 309 (a) No building permit or certificate <br />of occupancy shall be issued by the Building Official <br />if the structure to be constructed or the portion to <br />be remodeled lies within or fails to have the necessary <br />setback distance from any area reserved for the <br />construction, widening or extension of the city street <br />system pursuant to action taken by the Council of the City. <br />" , (b) No building permit or certificate of occupancy <br />shall be issued by the Building Official if the <br />structure to ' be constructed or the portion to be <br />remodeled lies within any recorded property interest <br />held for public purposes or public utility purposes.'" <br />"Section 9.45 Section 2623.1 is hereby added to the Building <br />Code to read as follows: <br />"'Section 2623.1 Concrete Floors: This section shall <br />apply to habitable rooms of Group R-l and R-3 <br />occupancies only. <br />Ii , (1) Concrete slab floors shall have a minimum <br /> thickness of three and one-half inches <br /> (3-~") and shall be reinforced with six <br /> inch by six inch by ten (6"X6"XIO ga.) gauge <br /> wire mesh. , <br />'" (2) A waterproof moisture barrier approved by <br /> the Building Official shall be installed <br /> directly between the concrete slab floor <br /> and granular fill below and must extend <br /> to the outer edge of the foundation at its <br /> base. When the foundation and floor slab <br /> are not poured monolithically such moisture <br /> barrier may extend not more than two inches <br /> (2" ) into the joint between the foundation <br /> and floor slab. <br />II , (3) A granular fill of suitable consistency and <br /> thickness shall be provided directly under <br /> the concrete slab membrane to retard cap111ary <br /> action and shall be approved by the Building <br /> Official. <br />II I (4) On level lots the elevation of the concrete <br /> floor slab shall be six inches (6") above <br /> finished grade. On ~nimproved lots or <br /> sloping ground a six inches (6") elevation <br /> must be maintained "above finished grade.'" <br /> -7- <br /> ,. _.- . <br />