My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
Ord89 2004
RedwoodCity
>
City Clerk
>
Resolutions
>
City Council
>
Working
>
Ordinances
>
1980-1989
>
Ord89 2004
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/11/2019 3:14:07 PM
Creation date
10/11/2019 3:14:04 PM
Metadata
Fields
Template:
CC Index
CC Index - Document Type
Ordinance
Date
12/4/1989
Description
ORDINANCE AMENDING SECTIONS 9.2, 9.40, 9.60, 9.70, 9.80, AND 9.110, AND ADDING DIVISION 4 TO ARTICLE IX OF CHAPTER 9 OF THE CODE OF THE CITY OF REDWOOD CITY RELATING TO THE AVAILABILITY OF CODES ADOPTED BY REFERENCE, ADOPTING BY REFERENCE THE UNIFORM BUILDING CODE, 1988 EDITION, THE UNIFORM BUILDING CODE STANDARDS, 1988 EDITION, THE UNIFORM BUILDING SECURITY CODE, 1988 EDITION, THE UNIFORM HOUSING CODE, 1988 EDITION, THE UNIFORM MECHANICAL CODE, 1988 EDITION, THE UNIFORM PLUMBING CODE, 1988 EDITION, AND THE NATIONAL ELECTRICAL CODE, 1987 EDITION, AND ESTABLISHING A SEISMIC HAZARD IDENTIFICATION PROGRAM, RESPECTIVELY THE COUNCIL OF REDWOOD CITY DOES ORDAIN AS FOLLOWS: SECTION 1. Section 9.2 of the Redwood City Code is hereby amended to read as follows: "Section 9.2. Copies of each publication adopted by
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
24
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
<br />- DES: d;]( 11/07 /89 ( 0 2 9 / 7 ) <br />DES:c. 11/13/89R <br /> <br /> <br /> <br />laterally displacing a single brick relative to the <br />adjacent bricks in that wythe. The opposite head joint <br />of the brick to be tested shall be removed and cleaned <br />prior to testing. The minimum quality mortar in eighty <br />percent (80%) of the shear tests shall not be less than <br />the total of thirty (30) psi plus the axial stress in <br />the wall at the point of the test. The shear stress <br />shall be based on the gross area of both bed joints and <br />shall be that at which movement of the brick is first <br />observed. <br /> <br />(4) For each core test, the mortar joint of the outer wythe <br />of the masonry core shall be tested in shear by placing <br />the circular core section in a compression testing <br />machine with the mortar bed joint rotated fifteen (15) <br />degrees from the axis of applied load. The mortar <br />joint tested in shear shall have an average ultimate <br />stress of twenty (20) psi based on the gross area. The <br />average shall be obtained from the total number of <br />cores made. If test specimens cannot be made from the <br />cores taken, the shear value shall be reported as zero <br />(0) . <br /> <br />(5) Five percent (5%) of existing wall anchors utilized to <br />resist pull-out forces shall be tested, with a minimum <br />of four (4) tests per roof or floor, consisting of two <br />(2) tests at walls perpendicular to framing and two (2) <br />tests at walls parallel to framing. The test apparatus <br />shall be supported on the masonry wall at a minimum <br />distance of the wall thickness from the anchor tested. <br />The rod anchor shall be given a preload of three <br />hundred (300) pounds prior to establishing a datum for <br />recording elongation. The tension test load reported <br />shall be recorded at one-eighth inch relative movement <br />of the anchor and the adjacent masonry surface. <br />Results of all tests shall be reported. The report <br />shall include the test results as related to wall <br />thickness and joist orientation. The allowable <br />resistance value of the existing anchors shall be forty <br />(40) percent of the average of those tested anchors <br />having the same wall thickness and joist orientation. <br /> <br />(6) (a) All testing agencies and inspectors shall be <br />approved in writing by the Building Official. Testing <br />results and field observation reports shall be included <br />in the engineering reports submitted to the Building <br />Division. <br /> <br />(b) Allowable height-to thickness ratios for tested walls <br />are given in Table A-3 of this Appendix. Allowable <br />stresses for tested walls are given in Table A-4 of <br />this Appendix. <br /> <br /> <br /> <br />16 <br />2004 <br /> <br /> <br /> <br />~ _ _, ,'~ ~_m""___>_'___""",,,~_""'_ <br />
The URL can be used to link to this page
Your browser does not support the video tag.