<br />78 <br />Page 10 <br /> <br />Floor plan signs shall be printed in a nondecorative lettering which shall <br />not be less than three-sixteenths of an inch (3/16") in height and shall <br />provide a sharp contrast with the background. The information shall <br />accurately depict the layout of the floor where the sign is located. <br /> <br />(c) Public Address System. In buildings four (4) or more stories in height, a <br />public address system shall be installed for the exclusive use of Fire <br />Department personnel, peace officers, or other City enforcement personnel <br />according to specifications approved by the Fire Prevention Bureau. <br />Controls for, and access to, such system shall be installed on the ground <br />floor of the building at a location subject to the approval of the fire code <br />official. <br /> <br />(d) Fire Equipment. In buildings of four (4) or more stories in height, a <br />cabinet or other enclosed facility shall be provided in every stairwell, smoke <br />tower, or such similar structure on alternate floors, commencing with the <br />third floor, for the storage of fire hose and related equipment. Said <br />cabinets, devices, hoses and related equipment shall be furnished by the <br />building owner or property developer who constructs such building. All such <br />equipment and the specific location thereof shall be subject to the approval <br />of the fire code official. <br /> <br />(e) Communication in Buildings. Whenever the size, orientation, <br />construction and/or components of a building or structure attenuate public <br />safety radio frequency signals, an in-building communication system shall <br />be installed by the owner to enable point-to-point fire department radio <br />communications within, to, and from said building or structure. (Ord. No. <br />2242, S 2, 12-5-2002) <br /> <br />Section 12.20. SECTION 901.4.5 OF THE FIRED CODE ADDED. <br /> <br />Section 901.4.5 is hereby added to the Fire Code to read as follows: <br />Section 901.4.5. Multiple Fire Alarm Systems. <br /> <br />Multiple fire alarm systems within single protected premises are not permitted. <br />(Ord. No. 2242, S 2, 12-5-2002) <br /> <br />Section 12.21. SECTION 901.10 OF THE FIRE CODE ADDED. <br /> <br />Section 901.10 is hereby added to the Fire Code to read as follows: <br /> <br />Section 901.10. Alarm Response, Violations. <br /> <br />Section 901.10.1 In General. It shall be a violation of this Code to cause the <br />fire department to respond to more than two (2) unintentional alarms in a sixty <br />(60) day period at a business or residence. <br /> <br />Atty/Ord/Ord.293 <br />120407 <br /> <br />8 <br />