thickness shall be provided directly under the concrete slab vapor barrier to <br /> retard capillary action. Two (2) inches of sand shall be provided between the <br /> vapor barrier and the concrete slab. The top of the concrete floor slab shall be a <br /> minimum six (6) inches above exterior finished grade. <br /> <br /> Sec. 9.74 SECTION 2204 OF THE BUILDING CODE AMENDED: Section 2204 <br />of the Building Code is hereby amended to read as follows: <br /> <br /> Section 2204.1 Load and Resistance Factor Design. Steel design based on load <br /> and resistance factor design method shall resist the factored load combinations <br /> of section 1612.2 in accordance with the applicable requirements of Section <br /> 2205. <br /> <br /> Section 2204.2 Allowable Stress Design. Steel design based on allowable <br /> stress design methods shall resist the factored load combinations of section <br /> 1612.3 in accordance with the applicable requirements of Section 2205. <br /> <br /> Sec. 9.75 SECTION 2205.3 OF THE BUILDING CODE AMENDED: Section <br />2205.3 of the Building Code is hereby amended to read as follows: <br /> <br /> Section 2205.3 Seismic Design Provision for Structural Steel. Steel structural <br /> elements that resist seismic forces shall, in addition to the requirements of <br /> Section 2205.2, be designed in accordance with Division IV. <br /> <br /> Sec. 9.76 DIVISION IV AND V OF CHAPTER 22 OF THE BUILDING CODE <br />ARE DELETED IN THEIR ENTIRETY. <br /> <br /> Sec. 9.77 DIVISION IV OF CHAPTER 22 OF THE BUILDING CODE IS ADDED <br />TO READ AS FOLLOWS: <br /> <br /> Division IV - SEISMIC PROVISIONS FOR STRUCTURAL STEEL BUILDINGS <br /> Based on Seismic Provision for Structural Steel Building, of the American <br /> Institute of Steel Construction, Parts I and III, dated April 15, 1997 and <br /> Supplement No. 2, dated November 10, 2000. <br /> <br /> Sec. 9.78 SECTION 2210 OF THE BUILDING CODE AMENDED: Section 2210 <br />of the Building Code is hereby amended to read as follows: <br /> <br /> Section 2210 Adoption. Except for the modifications as set forth in Section 2211 <br /> and 2212 of this Division and the requirements of the Building Code, the seismic <br /> design, fabrication and erection of structural steel shall be in accordance with the <br /> Seismic Provisions for Structural Steel Buildings, April 15, 1997 published by the <br /> American Institute of Steel Construction, 1 East Wacker Dr., Suite 3100, <br /> Chicago, II 60601, as if set at length herein. The adoption of Seismic Provisions <br /> for Structural Steel Buildings in the Division, hereinafter referred to as AISC- <br /> Seismic, shall include Parts I (LRFD) and III (ASD) and Supplement No. 2, dated <br /> November 10, 2000. <br /> <br />Atty/Ord/Ord. 167 <br />102402 14 <br /> <br /> 2241 <br /> <br /> <br />