My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
Ord02 2241
RedwoodCity
>
City Clerk
>
Ordinances
>
2000-2009
>
2002
>
Ord02 2241
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/5/2005 3:01:52 PM
Creation date
1/7/2003 10:44:01 AM
Metadata
Fields
Template:
CC Index
CC Index - Document Type
Ordinance
Agency Type
City Council
Date
12/2/2002
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
29
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
Section 336-4 Uses Permitted. Type NM, Type NMC, and Type NMS cables shall <br /> be permitted to be used in the following: <br /> <br /> (1) One and Two-Family dwellings. <br /> <br /> (2) Multifamily dwellings permitted to be of Types III, IV, and V <br /> construction except as prohibited in Section 336-5. <br /> <br /> (3) Other structures permitted to be of Types III, IV, and V construction <br /> except as prohibited in Section 336-5. Cables shall be concealed <br /> within walls floors, or ceilings that provide a thermal barrier of <br /> material that has at least a 15-minute finish rating as identified in <br /> listings of fire-rated assemblies. <br /> <br /> (4) Cable trays, where the cables are identified for such use. <br /> <br /> Sec. 9.145 SECTION 625.29 OF THE ELECTRICAL CODE AMENDED: <br />Section 625.29 of the Electrical Code is hereby amended to read as follows: <br /> <br /> Section 625.29 (D) (1) Ventilation Required. <br /> <br /> (1) Table Values: For supply voltages and currents specified in Table 625-29 <br /> (D)(1) or 625-29 (D)(2). The minimum ventilation requirements shall be as <br /> specified in Table 625-29(D)(1) or Table 625-29(D)(2) for each of the total <br /> number of electric vehicles that can be charged at one time. <br /> <br /> Sec. 9,146 SECTION 690 OF THE ELECTRICAL CODE AMENDED: Section <br />690 of the Electrical Code is hereby amended to read as follows: <br /> <br /> Section 690 Solar Photovoltaic Systems. Article 690 of the 2002 NEC may be <br /> substituted in its entirety for the installation of photovoltaic systems. <br /> <br /> Sec. 9.147 SECTION 692 OF THE ELECTRICAL CODE ADDED: Section 692 <br />of the Electrical Code is hereby added as follows: <br /> <br /> Section 692 Fuel Cell Systems: Article 692 of the 2002 NEC is hereby adopted in <br /> its entirety. <br /> <br /> Sec. 9.148 SECTION 695 OF THE ELECTRICAL CODE AMENDED: Section <br />695 of the Electrical Code is hereby amended to read as follows: <br /> <br /> Section 695 Fire Pumps. Article 695 of the 2002 NEC is hereby adopted in <br /> its entirety. <br /> <br />SECTION 7. Divisions 1, 2 and 3 of Article IX of Chapter 9 of the Code of the City of <br />Redwood City are hereby added to read as follows: <br /> <br /> Atty/Ord/Ord. 167 <br /> 102402 24 <br /> <br /> 2241 <br /> <br /> <br />
The URL can be used to link to this page
Your browser does not support the video tag.