Laserfiche WebLink
ATTY/RESO.0108/PC RESO RECOMMENDING APPROVAL OF DTPP 1330 ECR <br />REV: 01-11-23 JB <br />Page 18 of 23 <br />Street Infrastructure Improvements 45. Repair or Replace Street Infrastructure - Restore streets surrounding the project site to the satisfaction of the City Engineer at project completion. When this requires additional pavement restoration, the Engineer shall approve the preferred layout of pavement markings. [SDR][ENGINEERING] 46. Parking Garage Ramps - Parking garage ramps shall meet the Design Criteria of the Engineering Standards and consider safety and visibility of pedestrians to the satisfaction of the City Engineer. Access controls shall be designed and placed in such a way that vehicles do not block the public sidewalk or queue in the public right-of-way. The access control system shall be delineated in the building permit submittal. Person doors with panic hardware and alarms shall be installed at or adjacent to gates between private and public parking to allow the safest emergency egress path of travel. [SDR][ENGINEERING] 47. Shoring for Excavations – No tiebacks shall extend into the public right of way or onto adjacent properties without the written agreement of the City and/or private property owner. Any tie-backs within the City’s right of way shall be de-tensioned prior to permit sign-off and/or project acceptance. [COA] [ENGINEERING] Fire and Safety 48. Radio Coverage for Emergency Responders – All building and parking garages shall have approved radio coverage for emergency responders within the building. Upon completion of the building construction, a radio coverage test shall be conducted per the applicable codes and standards and if the test fails an Emergency Responders Radio Coverage System shall be installed. Verify any Blue Box phone communication requirements with the Redwood City Police Department. [COA][POLICE] <br />49. Addressing and Access – The following requirements apply: [COA][FIRE] a. Addresses must be logical, sequential numbers, i.e. First Floor 101, 102, 103, Second Floor 202, 203, 204, as opposed to F303, G401, etc. b. Floor plan maps shall be submitted with unit numbers at all entrances, excluding fire exits. c. Provide a keypad with 24 hour access code for public safety personnel at the main entrance, as opposed to just RFID readers or similar devices. <br /> 50. Elevator Requirements – The following requirements for elevators apply: [SDR][BUILDING] a. One elevator shall be available for use as an accessible means of egress in case of emergency. b. One elevator shall be connected to backup generator power in order to remain operable during emergencies. This elevator shall be provided with appropriate signage and shall extend to all floors including the lower levels of the parking