My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
Agmt24 Columbia Electric, Inc.
RedwoodCity
>
City Clerk
>
Agreements
>
2020-2029
>
2024
>
Under $106K
>
Agmt24 Columbia Electric, Inc.
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2024 3:19:53 PM
Creation date
8/22/2024 3:19:42 PM
Metadata
Fields
Template:
Agreement
PROJECT NAME
Installation of RRFB Project
Date
8/16/2024
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
39
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
REV: 12-21-2020 PR <br />Specifications. One continuous, unbroken length shall be used to form a loop of the <br />number of turns required and the lead-in from loop to junction box. <br />L. The lead-ins from the detector shall be Type B, lead-in cable shall be insulated with 20 <br />mils of high-density polyethylene. The conductors shall be twisted together with at least 2 <br />turns per foot and the twisted pair shall be protected with a copper or aluminum polyester <br />shield. A No. 20, minimum, copper drain wire shall be provided and connected to the <br />equipment ground within the cabinet. The cable shall be provided with a high-density <br />polyethylene or high-density polypropylene outer jacket with a nominal thickness of 32 <br />mils. An amorphous interior moisture penetration barrier of nonhydroscopic polyethylene <br />or polypropylene fillers shall be provided in accordance with Section 86-1.02F(2)(c)(iii) <br />“Inductive Loop Conductors” and 87-1.03V(2) “Inductive Loop Detectors”. The lead-in <br />shall be spliced, soldered and taped to the loop at the junction box. The shield shall be <br />connected to the controller cabinet ground bus. Where spade terminals are used to <br />secure the lead-in wire to field terminal blocks, the spade terminals shall be soldered as <br />well as crimped to the UF wire. All detector lead-in cable shall be continuous - no splicing <br />is permitted. <br />M. After the loop conductors are installed in the pavement, the slots shall be filled to within <br />1/8” of the pavement surface with the appropriate sealant. All excess shall be removed. <br />N. Detector loop lead-ins shall be installed in conduit from the gutter to the splice box. After <br />installation of loop wires, gutter end of conduit is to be sealed with duct seal and excavation <br />is to be filled with sand to within 1-1/2" of road surface and capped with asphalt. <br />O. All splices shall be soldered to ensure constant low resistance and must be insulated in <br />such a manner that the installation maintains resistance to ground of not less than 100 <br />megaohms. To ensure that the loop installation is correct, a continuity check of the loop <br />writing and a resistance check of this loop-to-ground shall be performed using a "megger" <br />or other suitable insulation tester, with a representative of the City Engineer present. Loop <br />readings that decrease below 20 megaohms during the guarantee period shall be <br />considered below minimum limits and shall require replacement. <br />P. The contractor shall test the detectors with a motor-driven cycle, as defined in the <br />California Vehicle Code, that is licensed for street use by the Department of Motor Vehicles <br />of the State of California. The unladen weight of the vehicle shall not exceed 200 pounds <br />and the engine displacement shall not exceed 100 cubic centimeters. Special features, <br />components or vehicles designed to activate the detector will not be permitted. The <br />contractor shall provide an operator who shall drive the motor-driven cycle through the <br />response or detection area of the detector at not less than three (3) miles per hour nor <br />more than seven (7) miles per hour. The detector shall provide an indication in response <br />to this test. <br />Q. Chevron asphalt loop sealant or equal shall be used. <br />R. Adjacent loops shall be tied to the same four-channel detector. <br />S. The number of lead-in-cable required to achieve the specified detection shall be installed. <br />T. Where Type "A" loops are indicated on the plans, except for speed monitoring installation, <br />a six-foot diameter circular loop may be installed in lieu of the shape shown on the plans. <br />The sides of the slot shall be vertical and the minimum radius of the slot entering and <br />leaving the circular part of the loop shall be 1-1/2 inches. <br />U. If any part of the loop conductor, including the portion leading to the adjacent pull box, is <br />damaged by the contractor's operations, the entire detector loop shall be replaced. If any <br />adjacent loop is damaged during such replacement, that loop shall also be replaced.
The URL can be used to link to this page
Your browser does not support the video tag.