My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
Reso23-22 0110 PC23-22 PC Reso Stanford Block C
RedwoodCity
>
City Clerk
>
Resolutions
>
Planning Commission
>
2023
>
Reso23-22 0110 PC23-22 PC Reso Stanford Block C
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/21/2024 2:49:01 PM
Creation date
10/21/2024 2:48:50 PM
Metadata
Fields
Template:
CC Index
CC Index - Document Type
Resolution
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
26
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
4855-3069-9660 v1 <br />Department and provide the observed flow, the available flow at 20psi, and the required fire flow <br />in accordance with Appendix B as noted above. The required fire flow, as required by the CFC <br />Appendix B must be provided on the building permit plans prior to the project proceeding with <br />construction. [COA][ENGINEERING AND FIRE] <br />50.Fire Department Knox Building Access – A Knox Key box is required as part of this project to allow <br />emergency access for firefighters. Indicate on the plans that a Knox key box will be provided on the <br />building at a location approved by the Fire Department. (CFC 506). [SDR][FIRE] <br />51.Radio Coverage for Emergency Responders – All building and parking garages shall have approved <br />radio coverage for emergency responders within the building. Upon completion of the building <br />construction, a radio coverage test shall be conducted per the applicable codes and standards and <br />if the test fails an Emergency Responders Radio Coverage System shall be installed. Verify any Blue <br />Box phone communication requirements with the Redwood City Police Department. [COA][POLICE] <br />52.Portable Fire Extinguisher Required – Portable fire extinguishers, with a minimum classification of <br />2A:B:C are required to be permanently installed in the building within 75 feet of travel from all <br />portions of the building in compliance with NFPA 10 and CFC Section 906. Indicate the location and <br />size of these fire extinguishers on the plans. Provide a section detail indicating how the fire <br />extinguishers are to be mounted to the building. [SDR][FIRE]. <br />53.Combination Sprinkler/Standpipe System – The California Fire Code requires building four or more <br />stories in height to be provided with a Class 1, manual standpipe system. Provide plans for the <br />design of this system or indicate the requirements for this system and list the design and installation <br />as a deferred submittal on the cover sheet of the plans prior to installation of the system. NOTE: <br />The design of the fire sprinkler system must be an NFPA 13 system. The notation for deferred <br />submittals must indicate that the fire sprinkler system will be a combination sprinkler/standpipe <br />system with hose connections on all levels of the building. (CFC Section 905). [SDR][FIRE] <br />54.Fire Department Access Plan – Provide a fire department access plan that indicates all routes of fire <br />department road access required to within 150 feet of all portions of the exterior of the building <br />unless otherwise approved by the Redwood City Fire Department (CFC Section 503). <br />55.Addressing and Access – The following requirements apply: [COA][FIRE] <br />a)Addresses must be logical, sequential numbers, i.e. First Floor 101, 102, 103, Second Floor 202, <br />203, 204, as opposed to F303, G401, etc. <br />b)Floor plan maps shall be submitted with unit numbers at all entrances, excluding fire exits. <br />c)Provide a key pad with 24 hour access code for public safety personnel at the main entrance, <br />as opposed to just RFID readers or similar devices. <br />56.Elevator Requirements – The following requirements for elevators apply: [SDR][BUILDING] <br />a)One elevator shall be available for use as an accessible means of egress in case of emergency. <br />b)One elevator shall be connected to backup generator power in order to remain operable during <br />emergencies. This elevator shall be provided with appropriate signage and shall extend to all <br />floors including the lower levels of the parking structure. <br />c)All additional elevators shall be connected to battery backup with sufficient power to bring the <br />elevator to the exit level in the event of an emergency. <br />d)All elevators shall be equipped with smoke curtains. <br />ATTY/RESO.0110/PC RESO STANFORD BLOCK C - EXHIBIT A & B <br />REV: 11-30-23 VR Page 9 of 20
The URL can be used to link to this page
Your browser does not support the video tag.