My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
Reso24-02 0019 PC Reso 2336 El Camino Real
RedwoodCity
>
City Clerk
>
Resolutions
>
Planning Commission
>
2024
>
Reso24-02 0019 PC Reso 2336 El Camino Real
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/21/2024 3:00:47 PM
Creation date
10/21/2024 3:00:41 PM
Metadata
Fields
Template:
CC Index
CC Index - Document Type
Resolution
Text box
ID:
1
Creator:
REDWOOD_CITY\NANCYRAMIREZ
Created:
10/21/2024 3:00 PM
Modified:
10/21/2024 3:00 PM
Text:
https://www.municode.com/library/ca/redwood_city/codes/code_of_ordinances?nodeId=CH18LOIMPL_ARTXIVLODEST_S18.242UNUT
ID:
2
Creator:
REDWOOD_CITY\NANCYRAMIREZ
Created:
10/21/2024 3:00 PM
Modified:
10/21/2024 3:00 PM
Text:
https://www.municode.com/library/ca/redwood_city/codes/code_of_ordinances?nodeId=CH18LOIMPL_ARTXIVLODEST_S18.242UNUT
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
19
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
ATTY/RESO.0019/PC RESO 2336 EL CAMINO REAL <br />REV: 05-01-24 VR <br />Page 13 of 18 <br />b. Work requiring a grading permit. Grading permits require a Plot and Finished Grading Plan prepared by a California-registered Civil Engineer. c. Work requiring on-site shoring which affects the public right of way d. Work using the public right-of-way for any fixed structure (awnings, roof overhangs, fixed planters, etc.). Insurance, meeting the City’s standards, is required. This permit will be recorded against the property. 25. Undergrounding Utilities - The applicant shall underground all overhead utilities along Hemlock Avenue and Linden Street project frontage as Phase Two of the project, which shall be shown on the building permit plans. [SDR][ENGINEERING] 26. Sewer Capacity – Prior to encroachment permit issuance, submit to the City, and obtain approval of, an evaluation and report prepared by a licensed engineer demonstrating that the existing sewer mains have sufficient capacity for the project. The study shall consider existing, project, other approved projects, and applications currently under review in determining the needed capacity. If the existing sewer main is less than 6” in size, or is in any other way not sufficient as determined by the City Engineer, applicant shall, as part of the Project, construct and install new sewer mains sufficient to meet such requirements, in accordance with the City's Engineering standards and as directed by the City Engineer to the City Engineer's satisfaction. [SDR][ENGINEERING] 27. Sewer Lateral Limit – The project is limited to one sewer lateral per parcel. [COA][ENGINEERING] 28. Sewer Lateral Size for Commercial Development - For new or remodeled commercial buildings, sewer laterals less than 4” shall be upgraded to a minimum 6” size. [SDR] [ENGINEERING] 29. Water Mains – Prior to encroachment permit issuance, submit to City, and obtain approval of, an evaluation and report, prepared by a licensed engineer, in conformance with the City's Engineering Standards, demonstrating that the proposed water main meets the domestic and fire flow requirements in accordance with City Code Section 38.26 and the International Fire Code. If the existing water main is less than 6” in size, or is in any other way not sufficient as determined by the City Engineer, applicant shall, as part of the Project, construct and install new water mains sufficient to meet such requirements, in accordance with the City's Engineering Standards and as directed by the City Engineer. New water mains shall be 8” minimum in size and extend across the entire property frontage, from the nearest point of connection to an existing 6” or larger water main.[SDR][ENGINEERING] 30. Water Meters – The project is limited to one “master” water meter for domestic water service. Any metering for individual units must be accomplished by private sub-meters within the property. [COA][ENGINEERING]
The URL can be used to link to this page
Your browser does not support the video tag.