Laserfiche WebLink
REV: 04-29-25 LF <br />Cylinders in excess of 25 feet with the rod extended, or that require the attachment of the rod to <br />the mid-section, shall not be desirable for two (2) reasons that are not consistent with the level of <br />quality desired by the City: <br />•Rod attachment to the mid-section requires that the lower rung rail cannot be <br />sealed from the atmosphere and therefore long-term corrosion cannot be <br />adequately controlled. <br />•The cylinder shall be subjected to the buckling forces caused by normal ladder <br />deflection. <br />Cables attached to the base and mid ladder sections shall be routed over sheave wheels on the <br />base section and cylinder barrel. This cabling arrangement shall act as a stroke multiplier to <br />provide full-power ladder extension and retraction. Extension of the ladder sections shall be <br />accomplished by the movement of the cylinder barrel toward the turntable end of the base section, <br />thus providing better weight distribution when the ladder is extended. <br />Retraction of the ladder sections shall be accomplished by movement of the barrel toward the <br />outboard end of the base section, thus providing better weight distribution between front and rear <br />axles of the apparatus when stowed in the travel position. <br />The extension/retraction cables shall have a minimum safety factor of 5:1 and shall be of the <br />following diameters: <br />•Inner Mid Section: 1/2” <br />•Outer Mid Section: 3/8” <br />•Fly Section: 5/16”. <br />EXTENSION INDICATORS <br />Reflective numerals shall be affixed to the inside of the handrail of the base section opposite the <br />turntable control console. The numerals shall be at appropriate intervals indicating total aerial <br />extension in 10-foot increments. A band on the first fly section shall align with these marks at the <br />appropriate extension distance. An additional stripe shall be provided between the numbered <br />stripes to indicate each 5 feet of aerial extension. <br />The extension indicator color shall provide a high contrast with the color of the ladder section to <br />which it is applied. <br />This shall make the length of aerial extension easily readable by the operator by merely glancing <br />at the indicators. <br />The extension markers shall be provided in red reflective material. <br />LADDER SLIDE MECHANISM <br />UHMW slide pads shall be provided on each ladder section for load transfer between sections. <br />Slide pads shall be used on both upper and lower bearing surfaces and to control side sway of <br />the sections. <br />ATTY/AGR.2025.089/Fire Apparatus Solutions (Purchase of Spartan-LTC 105' TDA) (Page 137 of 150)