My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
Reso24-10 0080 PC Reso 590 Veterans & 91 Winslow Project
RedwoodCity
>
City Clerk
>
Resolutions
>
Planning Commission
>
2024
>
Reso24-10 0080 PC Reso 590 Veterans & 91 Winslow Project
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/6/2026 3:01:37 PM
Creation date
1/6/2026 3:01:26 PM
Metadata
Fields
Template:
CC Index
CC Index - Document Type
Resolution
Meeting Type
Regular
Agency Type
Planning Commission
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
28
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
ATTY/RESO.0080/PC RESO 590 VETERANS & 91 WINSLOW PROJECT – EXHIBIT A - COA <br />REV: 11-14-24 JB <br />Page 11 of 19 <br />voice/alarm communication system control unit), fire alarm annunciator panel (CFC <br />§907.6.4.3), fire pump status indicator, emergency and standby power status indicators, <br />generator supervision devices, manual start and transfer features, elevator lobbies and <br />waiting areas two-way communication system, and other features as needed to assist <br />with firefighting and rescue operations for arriving fire companies. <br /> <br />51. Automatic Fire Sprinkler System: An automatic fire sprinkler system is required to be <br />installed in accordance with Section 903.3.1.1 (NFPA 13), throughout all buildings with a <br />Group R fire area. [CFC§903.2.8] Provide plans and hydraulic calculations as a deferred <br />submittal for the design of the fire sprinkler system. <br /> <br />52. Fire Alarm System: An Underwriters Laboratories Central Station fully addressable fire <br />alarm systems is required to be installed throughout the building, and in compliance with <br />NFPA 72. The fire alarm systems must also be provided with Underwriters Laboratories <br />Central Station Monitoring Service. Provide plans and voltage drop calculations as a <br />deferred submittal for the design of the fire alarm system and identify the company <br />providing the Underwriters Laboratories Central Station Monitoring Service. <br /> <br />53. Emergency Responder Radio Coverage System (ERRCS): An emergency responder radio <br />coverage system (ERRCS) is required. [CFC §510.1] <br /> <br />54. Fire Apparatus Access Roads: An approved fire apparatus access road must be provided. <br />A Class I automatic wet standpipe system was approved as an alternate method for <br />compliance. [CFC §503.1.1] The approved Alternate Methods and Materials Request <br />(AMMR) shall be applied to the plans prior to building permit application. <br /> <br />55. Aerial Fire Apparatus Access: Buildings greater than 30 feet in height, require aerial <br />(ladder truck) fire apparatus access, positioned parallel to the long side of the building. <br />No overhead utility or power lines, horizontal or vertical fixed obstruction are to be <br />located along the aerial fire apparatus access road, nor can they be located between the <br />aerial fire apparatus access road and the building that may obstruct aerial fire apparatus <br />operations. [CFC Appendix D§105.1] The approved AMMR shall be applied to the plans <br />prior to building permit application. <br /> <br />56. Required Fire Flow: Based on the proposed construction type of Type III-A, at 119,085 <br />square feet, the required fire flow for this project is 5,000 GPM at 20 psi residual pressure. <br />After allowing for a 50% reduction due to the installation of automatic fire sprinklers <br />meeting section 903.3.1.1 of the 2019 CFC (NFPA 13), the required fire flow for this <br />project is 2,500 GPM at 20 psi residual pressure. [CFC §507.1] Based on the required fire <br />flow of 2,500 GPM at 20 psi residual pressure, the required number of fire hydrants is <br />three with a spacing of 450 feet in accordance with Appendix C of the CFC. <br /> <br />57. Class I – Automatic Wet Standpipe Hose Station Outlets: Automatic wet standpipes are <br />required to be provided as addressed in the Approved AMMR, signed November 3, 2022,
The URL can be used to link to this page
Your browser does not support the video tag.