My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
Agmt26 Water Supply Agrement Amended and Restated
RedwoodCity
>
City Clerk
>
Agreements
>
2020-2029
>
2026
>
Agmt26 Water Supply Agrement Amended and Restated
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/26/2026 11:56:04 AM
Creation date
6/26/2026 11:53:40 AM
Metadata
Fields
Template:
Agreement
Date
2/19/2026
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
281
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
<br /> 27 <br />2025 Amended and Restated WSA 21945395.2 <br />replace them when necessary, in order to ensure that their accuracy is consistent with <br />specifications provided in Attachment J. <br />D. The SFPUC shall continue to contract with a qualified independent metering <br />consultant to perform periodic inspection, testing, servicing and calibration of the County-Line <br />Meters, the In-City Terminal Reservoir Meters, and the System Input and In-Line Meters <br />described in Attachment J, as well as the portion of the SFPUC’s Supervisory Control and Data <br />Acquisition (SCADA) system that utilizes the flow signals produced by that measuring and <br />recording equipment. The method, schedule and frequency for calibration and maintenance of <br />the County-Line Meters and the In-City Terminal Reservoir Meters are specified in Attachment <br />J. The SFPUC shall provide copies of the metering consultant's reports to BAWSCA. <br />E. System Input Meters measure water deliveries into the Regional Water System <br />from sources such as Hetch Hetchy and the SFPUC’s water treatment plants. System Input <br />Meters also measure deliveries from the Regional Water System to outside sources or from <br />such sources to the Regional Water System through interties with the Santa Clara Valley Water <br />District and the East Bay Municipal Utility District. In-Line Meters measure internal system flows <br />and are located on the Bay Division Pipelines and other main transmission pipelines. These <br />meters are collectively referred to as the “System Input and In-line Meters.” Similar to the <br />County-Line Meters, the System Input and In-Line Meters have secondary metering equipment, <br />such as differential pressure transmitters and flow recorders. The System Input and In-Line <br />Meters, and all associated secondary metering equipment, shall be calibrated and maintained <br />according to the method, schedule, and frequency specified in the Procedures Manual <br />described in subsection G, below. <br />F. The locations of the smaller and more numerous meters described in subsection <br />B (4) and (5) are not illustrated in Attachment J; however, they are also critical in the <br />determination of cost allocations, and accordingly require continued maintenance and <br />calibration. It is the responsibility of the SFPUC to maintain the accuracy of these meters and <br />their secondary metering equipment. <br />G. The SFPUC will prepare a Procedures Manual which will describe in detail the <br />procedures for periodic inspection, testing, servicing and calibration of the measuring and <br />recording equipment described in subsection B. Once the Procedures Manual is completed, the <br />SFPUC and BAWSCA may agree that it should supersede some or all of the requirements in
The URL can be used to link to this page
Your browser does not support the video tag.