My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
Agdapkt 2010-12-06 clsd and regular
RedwoodCity
>
City Clerk
>
Agenda Packets
>
2010-2019
>
2010
>
Agdapkt 2010-12-06 clsd and regular
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/9/2012 10:25:30 AM
Creation date
12/2/2010 3:32:47 PM
Metadata
Fields
Template:
CC Index
CC Index - Document Type
Agenda Packet
Meeting Type
Joint
Agency Type
City Council and Redevelopment Agency
Date
12/6/2010
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
386
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
7.A <br /> Page 5 <br /> Section 109.2 Schedule of Fees. The Building Official shall charge a fee to the <br /> person filing an application or requesting services for such permit, such fee to be <br /> established by resolution of the Council. <br /> Sec. 9.43. SECTION 9.43 ADDED TO THE BUILDING CODE: Section 9.43 is <br /> hereby added to the Building Code to read as follows: <br /> Section 9.43. Very High Fire Hazard Severity Zone Map: <br /> The City Council hereby adopts and designates Very High Fire Hazard Severity <br /> Zones as recommended by the Director of the California Department of Forestry and <br /> Fire Protection and as designated on a map titled, `Redwaod City — Fire Hazard Map,' <br /> dated February 3, 2009, and retained on file and made available at the offices of the <br /> Fire Chief and Building Official of the City of Redwood City. The 'Redwood City — Fire <br /> Hazard Map' is also adopted in Section 12.7.1 of Article II of Chapter 12 of the <br /> Redwood City Municipal Code." <br /> Sec. 9.44. SECTION 903.2 OF THE BUILDING CODE AMENDED: Section <br /> 903.2 of the Building Code is hereby amended to read as follows: <br /> Section 903.2 Where required. Approved automatic sprinkler systems shall be <br /> required in new buildings and structures and in existing buildings and structures which <br /> add 1,000 square feet or more floor area. Refer to Article II of Chapter 12 of the <br /> Redwood City Municipal Code for specific requirements. The sprinkler systems shall <br /> also be provided in the locations described in Sections 903.2.1 through 903.2.12 of the <br /> Building Code, whichever is more restrictive. <br /> Sec. 9.45. TABLE. 1505.1 OF THE BUILDING CODE AMENDED AND <br /> SECTION 905.�.1 OF THE RESIDENTIAL CODE ADDED: <br /> Table 1505.1 of the Building Code is hereby amended to read as follows: <br /> TABLE 1505.1 <br /> MINIMUM ROOF COVERING CLASSIFICATION <br /> FOR TYPES OF CONSTRUCTION <br /> IA IB IIA IIB IIIA IIIB IV VA VB <br /> B B B B B B 6 B B <br /> Section 905.1.1 of the Residential Code is hereby added to read as follows: <br /> Section 905.1.1. Minimum Class B Roof Covering. Roof coverings shall be either <br /> Class A or Class B roof assemblies. <br /> Secs. 9.46 - 9.72. RESERVED. <br /> Atty/Ord/0rd.340 <br /> 112210 <br />
The URL can be used to link to this page
Your browser does not support the video tag.