Laserfiche WebLink
• <br /> 3.08 LUMINAIRES <br /> A. Prior to energizing a luminaire, the Tamp socket shall be set in the proper location for the required Tight <br /> distribution in accordance with the manufacturer's instructions for the type of distribution called for on the <br /> plans. <br /> B. Set fixtures level and flush with the roadway surface. <br /> - 3.09 PHOTOELECTRIC CONTROLS <br /> A. Photoelectric controls shall be installed as per the detail shown on the plans, and adjusted to point in the <br /> north direction. <br /> 3.10 STANDARDS AND PEDESTALS <br /> A. All poles shall be installed as shown, leveled and cleared of all concrete. <br /> B. Salvaged material not reused shall be delivered to the Redwood City Municipal Services Center located <br /> at 1400 Broadway, Redwood City, California. The cost of this shall be considered in the contract price <br /> paid under - the -work item involved and no additional compensation will be allowed therefore. <br /> C. All required drilling on poles, masts, mast arms and fixtures shall be done in the field after the pole (mast) <br /> has been satisfactorily installed, plumbed and cleaned. <br /> D. For bonding existing intersectional street lighting standards the contractor shall either install a 3/16 inch or <br /> larger brass bolt, or preferably a means to be provided by pole manufacturer on side of pole adjacent to <br /> hand -hole. The bolt shall be installed on the outside of the shaft near the base plate where it will be <br /> covered by the bolt cover. The shaft of the standard shall be drilled for no larger than a 1/4 inch hole near <br /> the base plate to provide passage for the bonding conductor. <br /> E. Payment for modifications for touch -up painting and bonding of existing standards shall be considered as <br /> included in the contract lump sum price paid for street lighting. <br /> 3.11 BONDING AND GROUNDING <br /> A. Bonding and grounding shall conform to the provisions in Section 86 -2.10 "Bonding and Grounding" of the <br /> Standard Specifications, these special provisions, the latest issue of the National Electric Code, Section <br /> 250- 91(c), and to Sections 2395.91(b) and (c)I of the State of California Low Voltage Electrical Safety <br /> Orders, Title 8. <br /> B. Grounding jumper shall be attached by means provided by pole manufacturer, if possible. If not, <br /> contractor shall provide a 3/16 inch or larger brass bolt in the standard or pedestal and shall be run <br /> through conduit to the ground rod or bonding wire in adjacent pull box. <br /> C. Grounding jumper shall be visible after cap has been poured on foundation. <br /> 3.12 REMOVING, REINSTALLING OR SALVAGING ELECTRICAL EQUIPMENT <br /> A. Salvaged electrical materials shall be hauled to the Redwood City Municipal Services Center located at <br /> 1400 Broadway, Redwood City, and stockpiled. <br /> B. Full compensation for hauling and stockpiling electrical materials shall be considered as included in the <br /> contract price paid for the item requiring the material to be salvaged and no additional compensation will <br /> be allowed therefore. <br /> 3.13 EXCAVATION AND BACKFILLING <br /> A. Excavation and backfilling for trenches, foundations and other appurtenance shall conform to the <br /> provisions in Section 86 -2.01, "Excavating and Backfilling" of the State Standard Specifications and <br /> Section 02202 of the Specifications. <br /> 3.14 DISPOSAL OF LOW SODIUM LAMPS <br /> A. All unserviceable, sodium lamps recovered from the existing street lights shall be brought to the Redwood <br /> City Municipal Services Center for disposal. <br /> B. Sodium can generate a high degree of heat when exposed to small amounts of water; therefore the <br /> following precautions must be taken while handling the lamps. <br /> 1. Prevent the bulb from being scratched. <br /> SIGNALS LIGHTING AND ELECTRICAL SYSTEMS 16500 -12 <br /> EMERGENCY VEHCILE PREEMPTION PROJECT 2010 <br />