Laserfiche WebLink
<br /> 5. \ c..-13 <br /> Attachment 'A' <br /> to the Water Supply Assessment for <br /> BAYSIOE GAROENS <br /> Projected Water Demand <br /> Date: 12/0812003 <br /> Prepared by BKF Engineers <br /> Water Unit lotal <br /> Number Persons/Unit Demand Demand <br /> Residential of Units (Per RWC) (GPCO) (GPO) <br /> 1 Bedroom 270 1.60 80 34,560 <br /> 2 Bedroom 295 2.50 80 59,000 <br /> ITotals I 565 I I 93,560 I <br /> Water Unit <br /> Demand <br /> (GPO/SF) <br /> or <br /> Rooms (GPO/Room) Total <br /> Area or or Demand <br /> Commercial (SF) Seats (GPO/Seat) (GPD) <br /> Leasino Office 3,150 0.13 410 <br /> Club House 3,400 0.13 442 <br /> Retail 4,300 0.13 559 <br /> Restaurant 4,000 125 30 3,750 <br /> ITotals I 14,850 I , 5,161 I <br /> Ilrrigation (140,000 SF @ 0.0717 GPD/SF)* I 10,042 I <br /> I Total I 108,762 I <br /> . Irrigation based on the following conversion <br /> 3.5 cu It of water/sq It of landscape per year x 7.48 gal/cu It x 1 year/365 days <br /> Onsite Existing Water Demand (from 1999 Meter Readings) <br /> Century Park 12 Theater I 16,457 I <br /> BKF Engineers Page 2 of 2 <br />