Laserfiche WebLink
7.A. - Page 40 <br /> Redwood City Chapter 3.Project Description <br /> project site represented a total of 8 percent of the total project site.During the Zoning <br /> Administrator's hearing,the four island, 16-fuel station was approved with a reduced number of <br /> islands and fuel stations with three islands and 12 fuel stations and,as a result,the planter increased <br /> in size to 6,316 sf and the overall landscape coverage increased to 9 percent.The proposed <br /> modifications would require the removal of the existing landscape planter adjacent to the fueling <br /> center.Four existing landscape islands within the parking field would be expanded by a total of <br /> 1,312 sf to replace some of the existing landscaping being removed for a net loss of approximately <br /> 5,004 sf,and would result in 8 percent of the total project site being landscaped.The landscape <br /> islands would be planted with similar species of trees,shrubs,and ground covers.Replacement <br /> landscaping would consist of 24-inch box trees, 15-gallon shrubs,and 1-gallon ground cover,with <br /> redwood mulch to match the existing landscaping.There are 271 existing trees on the project site. <br /> Approximately 16 trees would be removed for the proposed modifications and seven new 24-inch <br /> box trees would be planted for a total of 262 trees.The required number of trees (one tree per five <br /> stalls) is 150;the proposed modifications would exceed that number by 112 trees. <br /> Grading <br /> The existing landscape island adjacent to the fueling center provided for a sloped transition from the <br /> existing parking field to the fueling center,an approximate 20-inch difference in elevation.With the <br /> removal of the landscape island,a 20-inch poured-in-place retaining wall with 4-foot bollards would <br /> be constructed to make up the grade differential and provide additional safety to warehouse <br /> members. <br /> Canopy Design <br /> The existing 32-foot wide,88-foot long canopy over the fueling center would be extended by 64 feet <br /> for a total of 152 feet.The canopy's width would be maintained.The existing approximately 14-foot <br /> 6-inch minimum clearance and overall canopy height of 17-feet 6 inches would also be maintained. <br /> The extended canopy would be constructed with similar materials as the original approved canopy <br /> design. <br /> Signage <br /> The fueling center currently has illuminated Costco Gasoline signs on each of the four sides of the <br /> existing canopy.The existing signage would be replaced with new signage that would have a slightly <br /> modified design.Each sign would be approximately 6 sf smaller than the existing signs.The new <br /> signage would be installed and centered on the fascia of the expanded canopy.The signage would <br /> consist of externally illuminated panels consistent with the originally approved signage. <br /> Addendum No.2 to the Environmental Impact Report for September 2012 <br /> the Redwood City Costco Wholesale Project 3-Z ICF 00154.12 <br />