Search
Agmt13 Pacific Electric Contracting, Inc.
RedwoodCity
>
City Clerk
>
Agreements
>
2010-2019
>
2013
>
Agmt13 Under 60K
>
Agmt13 Pacific Electric Contracting, Inc.
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/11/2013 10:07:54 AM
Creation date
3/11/2013 9:43:40 AM
Metadata
Fields
Template:
Agreement
Contractor Name
Pacific Electric Contracting, Inc.
PROJECT NAME
East Bayshore Road Street Lighting Project
RMP File Number
304.5
Date
3/8/2013
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
93
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
A. Catch basins and manholes shail be covered when paving or applying seal coat, tack coat, <br /> slurry seal or fog seal. <br /> B. The Engineer may direct the contractor to protect drainage courses by using control measures <br /> such as earth dike, straw bale and sand bag to divert run-off or trap fiiter sediment. <br /> C. Excess sand (placed as part of a sand seal or to absorb excess oil) shall not be swept or <br /> washed down into gutters, storm drains or creeks. The sand shall be collected and returned to <br /> the stockpile or disposed of in a trash container or hauled to an approved dump site. Water <br /> shall not be used to wash down fresh asphalt concrete. <br /> 3.09 PAINTING <br /> A. The cleaning of painting equipment and toois shall be performed in a designated area that will <br /> not enter the gutters, storm drains or creeks. <br /> B. Excess paint shall be removed from brushes, rollers and equipment prior to cleanup. <br /> C. Wash water from aqueous cleaning of water-based paint tools and equipment shall be disposed <br /> of in a sanitary sewer or onto a designated dirt area. <br /> D. Paint thinners and solvents from oil-based paints shall be filtered and re-used when possible. <br /> Waste sludge, thinner and solvent from cleaning tools and equipment shall be disposed of as a <br /> hazardous waste. <br /> 3.10 SITE CLEANUP <br /> A. The cieaning of equipment of materials shali not be performed on-site or in the street using <br /> soaps, solvents, degreasers, steam cleaning or equivalent methods. <br /> B. All cleanup must be performed in a designated area that will not allow the cleaning rinse to flow <br /> off-site or into streets, gutters, storm drains, or creeks. <br /> * * * <br /> STORMWATER POLLUTION PREVENTION 02133-4 <br /> EAST BAYSHRORE ROAD STREET LIGHTING PROJECT <br />