C. Forms shall be carefully set to the alignment and grade established and shall conform to the <br /> required dimensions. Forms shall be rigidly held in place by stakes set at satisfactory intervals. <br /> Sufficient clamps, spreaders and braces shall be installed to insure the rigidity of the forms. <br /> D. Forms for back and face of curbs, lip of gutters and edge of walks, valley gutters or other <br /> surface slabs shall be equal to the full depth of the concrete as shown, noted or called for on the <br /> plans or detail drawings. Composite forms made up from benders or thin planks of sufficient ply <br /> to ensure rigidity of the form in the shape required may be used on curves and curb returns. <br /> 3.04 PLACING STEEL REINFORCEMENT <br /> A. Bars shall be free of mortar, oil, dirt, excessive mill scale and scabby rust and other coatings of <br /> any character that would destroy or reduce the bond. All bending shall be done cold, to the <br /> shapes shown on the plans. The length of lapped splices shall be as follows: <br /> 1. Reinforcing bars No. 8, or smaller, shall be lapped at least 45 bar diameters of the smaller <br /> bar joined, and reinforced bars Nos. 9, 10, and 11 shall be lapped at least 60 bar <br /> diameters of the smaller bars joined, except when otherwise shown on the plans. <br /> 2. Splice locations shall be made as indicated on the plans. <br /> B. Reinforcement shall be accurately placed as shown on the plans and shall be firmly and <br /> securely held in position by wiring at intersections and splices and by using precast mortar <br /> blocks or ferrous metal chairs, spacers, metal hangers, supporting wires, and other approved <br /> devices of sufficient strength to resist crushing under applied loads. Supports and ties shall be <br /> such as to permit walking on reinforcing without undue displacement. <br /> C. Reinforcing shall be placed so as to have the following minimum concrete cover: <br /> Surfaces exposed to water 4" <br /> Surfaces poured against earth 3" <br /> Formed surfaces exposed to earth or weather 2" <br /> Slabs, walls, not exposed to weather or earth 1" <br /> D. Minimum spacing, center of parallel bars shall be two and one half (2-1/2) times the diameter of <br /> the larger sized bar. All reinforcing shall be securely tied in place prior to pouring concrete. <br /> Placing of dowels or other reinforcing in the wet concrete is not permitted. <br /> 3.05 MIXING CONCRETE <br /> A. All concrete shall be transit mixed in accordance with the requirements of ASTM Designation <br /> C94. Transit mixed concrete shall be mixed for not less than ten (10) minutes total, of which not <br /> less than three (3) minutes shall be on the site just prior to pouring. Mixing shall be continuous <br /> with no interruptions from the time the truck is filled until the time it is emptied. Concrete shall <br /> be placed within one hour of the time water is first added. <br /> B. Hand mixing of concrete for use in concrete structures will not be permitted. <br /> 3.06 PLACING CONCRETE <br /> A. Subgrade sha�l be thoroughly wetted prior to the placing of concrete for all concrete placed <br /> directly on soil. All standing water shall be removed prior to placing of concrete. <br /> B. No concrete shall be placed until the subgrade and the forms have been approved. <br /> C. Concrete shall be conveyed from mixer to final location as rapidly as possible by methods <br /> preventing separation of the ingredients. Deposit concrete as nearly as possible in final position <br /> to avoid re-handling. <br /> D. Concrete shall be placed and compacted in forms without segregation by means of inechanical <br /> vibration or by other means as approved by the Engineer. Vibration shall continue until the <br /> CONCRETE IMPROVEMENTS 02550-6 <br /> EAST BAYSHRORE ROAD STREET LIGHTING PROJECT <br />