Laserfiche WebLink
7.A. - Page 62 <br /> 62. The minfmum number of fire hydrants and spaci�g requiremen�s avaiEable <br /> fa the bu�lc€ir�g shall no# be less #�an that iisted in Internatior�al Fire Code <br /> Appendix C, unless an alternati�re methods and means of pro�ection has <br /> beer� appro�ed by the Fire Marshal. <br /> 63. All vaf�es controlling the water supply far automatic#ire �p�inkler systems, <br /> pumps, and water �ow switches nn ail �re sprink[er syst�ms shall be <br /> e[ec�ronieafly s�pervised. (IFC 903.4) <br /> 64. A manua! fire alarm system shall be installed in Group R-2 accupancies, <br /> Manuaf fire �farm boxes are not required throughout the build[ng when the <br /> bu[Iding is equip�ed throughout with an autamatic �ire sprir�kfer sysfem <br /> and no�ificatiot� appfiances acfivate upor� sprinkier flow- At I�as# one <br /> rnanual station si�all be installed at an a�proved location. A11 in�tiating and <br /> indicating devices shall be �lecfranically supervised. (Title 2�4, Pa� 9, <br /> CCR, Sec�ion 907.2.9) <br /> B5. Far �e purpose of fre alarm annunciation, each #ioor of the buiEding shall <br /> be cansidered as a separata zone. (NFPA 72- 2407 Edition, Section <br /> 4.4.6.6.1) . <br /> fi6. �ire alarm sigr�als sha�l be transmitted ta the central station and <br /> retransmitted by zone to the �ublic safety communications c�nt�r <br /> (�rdinance 2326). <br /> 67. Single or multipie station smoke alarms shall be insta�led and maintained <br /> in Grot�p R-2 and R-3 occupancies regardless of occ�pa�t foad at all the <br /> falfawing locatians: <br /> a. On the ceilir�g or wa(I outside of each separate sieeping ar�a <br /> � in fhe irrtmediate vicin�ty at bedrvams. <br /> b. Ir� each ronm used#o�sleeping pt�rposes. <br /> c. IR enclosed common sfairv�►ells of apartment campfexes and <br /> afher multipte-dwelling comp(exes. <br /> {Titls 24, F'art 9, CCR, Sectipn 9U7.2.1 D.4.2) <br /> 68. M��tiple fire alarm systems within singfe profected p�em3ses are not <br /> permitt�d. <br /> � 68, All �ire alarm systems shall be certi�ied �y the Underwriters Laboratories <br /> (Ordinance 2326). <br /> 7'0. Key boxes of �sufFc�ent size shalf 'be ir�sfalled at a[f er�h'ances to the <br /> building. These key boxes sf�alf contain sufficient numbers of#ceys to allaw <br /> access to a!f parts of the bui{ding as well as #�te fi�e p�otsction equipment <br /> an� systems. L.ifierature frorn #he manufact�rer of these pro�ucts and <br /> ardering infarmat'ron can be obtained fram the Fire Departrr�enfi by cafling <br /> (650} 78Q-7400 or at www.knoxbox.G0i1'1. (IFC 546.1) <br /> ATiY/R55p.2745/PC AETFS HARBOR PRO�ECT <br /> REV:10-25-12 VR <br /> Page 11 of 15 <br />