Laserfiche WebLink
� . . 8.A. - Page 8 : - <br /> What the Guideline What the Applicant Focus of AAC review and <br /> Section Page Recommends Proposes recommendation <br /> 2.2.4.2-a 51 Maximum Establishment The Bradford and The review focused on the <br /> LenQth: Each retail space Middlefield Street sides of SMCU single use along <br /> should occupy no more than the 10,000 s.f. retail space long portions of the <br /> 25'of frontage on each street are occupied by a single frontage along Bradford <br /> which it faces. use, the SMCU use,which and Middlefield as noted. <br /> is longer than 25' on each The AAC accepted the <br /> street frontage (96' and proposed design variation. <br /> 144'feetrespectively). <br /> AAC The SMCU represents an existing use with a longstanding presence on this block; therefore, the <br /> Response use should be accommodated within the proposed building. Furthermore, the physical space both <br /> internally and as expressed architecturally with the exterior storefront bays can easily be demised <br /> into 25 foot storefronts should a tenant change occur. The AAC accepted the proposed design <br /> variation. <br /> 2.8.3.C.2-a 98 BuildinQ Base Facade Sheet A3.0—Detail 3 The review focused on the <br /> Comqosition ReQUlations:The indicates a pilaster question if the residential <br /> horizontal width of a dimension of 4 feet 8 entry feature warranted a <br /> protruding pilaster should be inches wide around the more substantial design <br /> at least 18 inches wide, but Residential Common element, or should the <br /> should not exceed 4 feet in Entrance. pilaster dimension be <br /> width reduced.The AAC <br /> accepted the design as <br /> proposed. <br /> AAC The residential entry feature was considered an entry feature, rather than a pilaster, and <br /> Response concluded that it warrants the additional size to be consistent with the proportions of the <br /> building. Pilasters are typically used to help define the rhythm of a street wall in a sequence of <br /> repetitive elements, such as the 25 foot storefront increments. The entry feature is intended to <br /> pronounce the point of access and create a statement, which can be visually distinct from the <br /> other architectural components of the building fa�ade, especially at the ground floor. <br /> 2.8.3.F.2-a 99 BuildinQ Base Facade Sheet A2.1-The Jefferson The review focused on the <br /> Comqosition ReQUlations: and Middlefield frontages fact that the Project has <br /> Secondary Entrances,Service have a variety of project tried to minimize this <br /> Entrance, Garage Entrance, elements that result in potential issue through <br /> and No Entrance Private Inactive Frontages,which variation in finish <br /> Frontage types are considered exceed the 25 foot materials and landscaping. <br /> "Inactive Frontages." No more increment, such as: The AAC concluded that <br /> than 25%or 25',whichever is • Electrical rooms the Project effectively <br /> greater,of any fa�ade's • Storage rooms minimizes the inactive <br /> Building Base (measured in . Parking Structure frontage areas by <br /> linear feet) should be • Detention Tank consolidating and locating <br /> occupied by Inactive . Transformer rooms on "away from the <br /> Frontages. Downtown Core". <br /> AAC The AAC requested that the project design team review the 150 foot increment surrounding the <br /> Response residential tower entrance on lefferson Avenue to determine if there is any additional opportunity <br /> to activate the spaces immediately adjacent to the entry. For example, the tower entry is flanked <br /> by a transformer room and garage entrances. <br /> Generally speaking the "Inactive Frontages"have been consolidated towards the north end of the <br /> Page 8 <br />