My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
AgdaPkt 2013-11-18 Special
RedwoodCity
>
City Clerk
>
Agenda Packets
>
2010-2019
>
2013
>
AgdaPkt 2013-11-18 Special
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2013 10:11:16 AM
Creation date
11/15/2013 3:48:02 PM
Metadata
Fields
Template:
CC Index
CC Index - Document Type
Agenda Packet
Meeting Type
Special
Agency Type
City Council
Date
11/18/2013
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
402
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
8.A. - Page 70 <br /> paid in accordance with Section 18.258 C of the Park Impact Fee Ordinance. <br /> 10. The owner/applicant shall pay a Traffic Mitigation Fee based on the <br /> schedule set by Ordinance, or as determined by a Traffic Study. <br /> 11. The property ownedapplicant shali apply for and obtain a Grading <br /> Permit. Prior to Grading Permit issuance, the applicant shall submit a Plot and <br /> Finished Grading Plan prepared by a California registered Civil Engineer. Grading shali <br /> be performed in accordance with Vofume fll, Parf II of the City's Engineering <br /> Standards www redwoodcitv orp/cdsfenaineerinq/standards/desiqn/PartV Submit cut/fil! <br /> volumes (CY) for all soils to be imported to or exported from the site. <br /> 12. Prior to issuance of any grading permit or other construction permit, <br /> the applicant shall obtain and submit to City and obtain approval of, a soiis report, <br /> prepared by a licensed geotechnical engineer, in conformance with Engineering <br /> 3tandards, Volumes II & III. <br /> 13. Prior to issuance of any grading permit or other construction permit, <br /> appiicant shall submit to Cify and obtain approval of, an evaluation and report, <br /> prepared by a licensed engineer, in conformance with the CiEy's Engineering <br /> Standards, demonstrating thaf the existing water main meets the domestic and fire <br /> flow requirements in accordance with City Gode Section 38.26 and the , <br /> International Fire Code. If the existing water main is not sufficienT as determined by <br /> the City Engineer, applicant shall, as part of the Project, construct and instali new <br /> water mains sufficient to meet such requirements, in accordance wi#h the Ciry's i <br /> Engineering Standards and as directed by the City Engineer. When the referenced � <br /> evaluation and reports have been submifted, and the proposed project design <br /> incorporates the necessary measures to implement the recommendations, the applicant <br /> may be required to update the referenced repo�ts should there be any material changes <br /> to the project. <br /> 1 <br /> 14. Prior to issuance of any grading permit or other construction permit, <br /> applicant shall submit to City and obtain approval of, an evaluation and report, ; <br /> prepared by a licensed engineer, in conformance with the City's Engineering � <br /> Standards, demonsfrating that the existing sewer mains have sufficient capacity for <br /> the Project. The study shall consider existing, project, other approved projects, and <br /> applications currently under review in determining the needed capacity. I# the ' <br /> existing sewer main is not sufficienfi as determined by the City Engineer, applicant ', <br /> shall, as part of the Project, construct and install new sewer mains sufficient to <br /> meet such requirements, in accordance with the City's Engineering standards and <br /> as directed by the City Engineer to the City Engineer's satisfaction, When the ; <br /> referenced evaluation and reports have been submitted, and the proposed project ' <br /> design incorporates the necessary measures to implement the recommendations, the � <br /> applicant may be required to update the referenced reports should there be any material <br /> changes to the project. <br /> i <br /> AT7Y/RE50.29D0(PC RESO APPROVING 525 MID�LEFlEIDTM,CONDO,PD&PC PERMIT '�� <br /> REV:08-Z9-13 VR <br /> Yagc G of 12 �'' <br />
The URL can be used to link to this page
Your browser does not support the video tag.