Laserfiche WebLink
01/13/2014 <br /> 903.2.13. Automatic Sprinkler Systems. In addition to the requirements for Automatic <br /> Sprinkler systems in this Code or the provisions of any other Code of the City, approved <br /> automatic sprinkler systems shall also be installed in the following buildings or <br /> structures: <br /> (a) New Buildings: All new buildings or structures with a total floor area of three <br /> thousand (3,000) square feet or more. <br /> (b) Existing Buildings: (i) Group R-3 occupancy dwellings and structures which add <br /> one thousand (1,000) square feet or more floor area, or are demolished to the <br /> foundation or structural framework; (ii) all other buildings or structures which add <br /> floor area so that the floor area of the existing building plus the floor area of the <br /> addition is three thousand (3,000) square feet or more. <br /> (c) Change in Occupancy Group: When there is a change in occupancy group or <br /> use from a less hazardous to a more hazardous occupancy group or use. <br /> (d) Limited area sprinkler systems: Existing Group R-2 occupancies, (apartment <br /> buildings) that have ground level, open parking garages, located below <br /> apartment units, and have direct access to a public way, will be required to <br /> install such a system as per section 903.3.5.1.1, when a permit for the <br /> installation of a new roof (re-roofl, has been issued by the City of Redwood City. <br /> Limited area sprinkler systems are exempt from fire department fees and are <br /> permitted to be supplied off of the buildings domestic water system. <br /> Sec. 12.19. SECTION 903.4.4 ADDED. <br /> Section 903.4.4 is hereby added to the Fire Code to read as follows: <br /> 903.4.4. Zone Transmittal. Fire alarm signals shall be transmitted by zone to the <br /> central station and retransmitted by zone to the public fire service communications <br /> center. <br /> Sec. 12.20. SECTION 903.4.5 ADDED. <br /> Section 903.4.5 is hereby added to the Fire Code to read as follows: <br /> 903.4.5. Service. All fire alarm systems shall be provided with central station service by <br /> the building owner. <br /> Sec. 12.21. SECTION 903.4.6 ADDED. <br /> Section 903.4.6 is hereby added to the Fire Code to read as follows: <br /> 903.4.6. Certification. All fire alarm systems shall be certificated by the Underwriters <br /> Laboratories. <br /> Sec. 12.22. SECTION 907.1 AMENDED ADDED. <br /> Section 907.1 is hereby amended to read as follows: <br /> 907.1. General. This section covers the application, installation, perFormance and <br /> maintenance of fire alarm systems and their components in new and existing buildings <br /> ATTY/ORD.397/FIRE CODE ORDINANCE ORD.#2402 <br /> REV:11-20-13 JS FORMERLY MUFF#305 <br /> Page 5 of 9 <br />