Laserfiche WebLink
I 7.1.L. - Page45 <br /> LINEAR-4 PRECAST GENERAL NOTES <br /> STORMFILTER DATA <br /> DESIGN WATER RATE(as) FLOW RATE WO XXX 1.)STORMFILTER BY CONTECH STORMVtATER SOLUTIONS.PORTLAND,OREGON 800548-9657. <br /> PEAK FLOW RAT£(Ire) XXX / <br /> RETURN PERIOD OF PEAK FLOW We) XXX 2.)FILTERS TO BE SIPHON-ACTUATED AND SELF-CLEANING. <br /> I OF CARTRIDGES REQUIRED XX 3.)PRECAST CONCRETE VAULT TO BE CONSTRUCTED IN ACCORDANCE OATH ASTM C857 <br /> CARTRIDGE FLOW RATE(15 GPM SID) XX AND C858. <br /> MEDIA TYPE XXXXIC 4.)STORMFILTER REQUIRES 2,3'OF DROP FROM INLET TO OUTLET. INLET AND OUTLET <br /> PIPING TO BE SPECIFIED BY ENGINEER AND PROVIDED BY CONTRACTOR. <br /> PIPE DATA: I.E. MATERIAL DIAMETER ; 5.)PRECAST STORMFILTER EQUIPPED WITH EITHER CORED OPENINGS OR KNOCKOUTS <br /> INLET PIPE II XXX.XX' XXX XX' AT INLET/OUTLET LOCATION. <br /> INLET PIPE 12 XXX.XX' XXX XX• 6.)RECOSIMENDE4 MAXIMUM DEPTH OF VAULT. DEPTH CAN RANGE. FROM 3.5'TO 5.5'RIM <br /> ,OUTLET PIPE XXX.XX' XXX XX' TO IE OUT. <br /> RIM ELEVATION(S): 7.)ANTI-FLOTATION BALLAST TO BE SPECIFIED BY ENGINEER IF NEEDED, BALLAST <br /> TO BE SET ALONG ENTIRE LENGTH OF 60111 SIDES OF VAULT. BALLAST <br /> MATERIALS TO BE PROVIDED BY CONTRACTOR. <br /> \ 8.)ALL STORMFTLTERS REQUIRE REGULAR MAINTENANCE. REFER TO OPERATION AND <br /> MAINTENANCE GUIDELINES FOR DETAILS. <br /> FLOW 0,)DETAIL REFLECTS DESIGN INTENT ONLY. ACTUAL VAULT DIMENSIONS AND CONFIGURATION <br /> WILL BE SHOWN ON PRODUCTION SHOP DRAWING. <br /> l0.)STANDARD DETAIL SHOWS MAXIMUM NUMBER OF CARTRIDGES. EXACT NUMBER REQUIRED <br /> I LADDER YES/NOl TO BE SPECIFIED ON SITE PLANS. <br /> ANTI-FLOTATION BALLAST 1 WI X• G DTH ,l HEIGHT [ <br /> 1 <br /> NOTES/SPECIAL REQUIRETIENIS: <br /> a <br /> 2'-3 1/2" <br /> --2'-9 1/2" J! <br /> LINEAR-4 STORMFILTER - SECTION VIEW .1-8 <br /> SCALE: N.T.S. 7 <br /> 10' <br /> 9'-2" <br /> ■, ■_I <br /> I I I <br /> 2' I II II <br /> I I I II <br /> I r Id I i <br /> • <br /> 3' <br /> . LINEAR--4 STORMFILTER - TOP VIEW 0 <br /> ME SYON.usvATEe AIR3fP£EME+Y <br /> SCALE: N.T.S. WATUNe.O <br /> U.5.PATENY iio.'5,322,629, <br /> No.5,707,827,No.6,027,639 <br /> No 5,649,045,No.5,624,575, <br /> AND RIM L15,AND TOOTGN <br /> PATENTS PENOXC <br /> ©2006 CONTECH Stornlwater Solutions <br /> SHEET DATE BY REVISION <br /> LINEAR-4 PRECAST STORMFILTER <br /> )NTECH Cit ' <br /> [2/2 DETAILS AND NOTES <br /> Q STANDARD DRAWING STORMWATER <br /> 2 1 Y/AG 1 .0114KVVE1 :856 75D ;;'�4$tIgCk� fg' t �G FILE NAME: — SCrEonT NSA <br /> DESIGNED : UHL '1 1/22/04— XXXX SFLIN4.0WG corltectletormwater,com <br />