My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
AgdaPkt 2014-06-23 Closed and Joint SA
RedwoodCity
>
City Clerk
>
Agenda Packets
>
2010-2019
>
2014
>
AgdaPkt 2014-06-23 Closed and Joint SA
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/19/2014 5:44:54 PM
Creation date
6/19/2014 5:24:15 PM
Metadata
Fields
Template:
CC Index
CC Index - Document Type
Agenda Packet
Meeting Type
Joint
Agency Type
City Council and Successor Agency
Date
6/23/2014
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
443
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
arras 7.3.E. - Page 17 <br /> be done by using fully-restrained pipe that can reliably <br /> stretch (yield) 1%; or have sufficient flexible joints to <br /> absorb the equivalent movement. <br /> b. Submit seismic design calculations to document the <br /> design and installation of pipes 16-inches in diameter <br /> (nominal) and larger, and of critical pipes regardless <br /> of size as determined by the City Engineer. The <br /> design procedure may follow guidelines in ALA <br /> (2005). <br /> c. Detailed seismic design calculations are optional for <br /> the remainder pipe sizes and classifications. Chart <br /> Method (ALA 2005) — Design Approach for Pipe <br /> Category C (Restrained Joints) - may be used for <br /> these pipes instead. <br /> d. Acceptable alternatives to meet this 1 percent strain <br /> are: <br /> Fully restrained High Density Polyethylene <br /> (HDPE) pipe with full penetration welds. <br /> ii. Or approved equals. <br /> e. All pipes to be provided with suitable corrosion <br /> protection. <br /> f. All designs to meet AVWVA requirements for all other <br /> loadings. <br /> g. Service laterals, blow offs, air and vacuum release <br /> and other appurtenances will be installed to resist the <br /> corresponding seismic loads, or installed in manner <br /> so that can be isolated (valved out) within 3 feet (1 <br /> meter) of the main. <br /> h. Alternative designs meeting the intent of ALA (2005) <br /> and the City Standards may be submitted. <br /> PART VII. WATER SYSTEM DESIGN CRITERIA <br /> Petrolatum wax tape system requirements for corrosion protection <br /> was added. <br /> New Paragrap <br /> PART XII. ATTACHMENTS <br /> Attachment T WATER SERVICE AREAS REQUIRING SEISMIC- <br /> DESIGNED WATER PIPES (NEW ATTACHMENT) <br />
The URL can be used to link to this page
Your browser does not support the video tag.