<br />Contract Amendment OIR <br />December 22,2005 <br />Revised January 17, 2006 <br />Redwood Shores Community Library <br /> <br />. <br /> <br />Eliminate the domestic hot water and domestic hot water return distribution piping and go with point <br />of use electric water heaters for all plumbing fixtures in the west side of the building. The original <br />design was not using the electric heaters to minimize the electric energy which is more valuable than <br />the gas energy. The redesign is owner directed revision to lower the construction budget. The <br />construction savings are much higher than the redesign fee therefore the revision is cost effective. <br />Change the reversed return heating hot water system to a direct return heating hot water distribution <br />system. The original design was for providing a better balanced system. The redesign is an owner- <br />directed revision to lower the construction budget. The construction savings are much higher than the <br />redesign fee therefore the revision is cost effective. <br /> <br />. <br /> <br />Structural <br />. Revise the entry ramp configuration <br />. Revise the rear deck and railing <br />. Simplify the fin elements <br />. Indicate test pile locations and provide test pile procedures on the structural drawings. The pile <br />locations and the test pile procedure are to be provided by the geotechnical engineer. Implementation <br />of the program and evaluation of the results are to be performed by the Geotechnical Engineer. <br /> <br />Electrical/Lighting <br />. Update quantity of fixtures for site lighting <br />. Review and decrease quantity of interior fixtures - Additional time required to select and specify <br />altemate light fixtures. This item requires review and re-specifying of a number of light fixtures <br />. Review type of dimming systems in multi-purpose rooms (3 total) - This change will require redesign <br />of the dimming system together with reconfiguring of the control system <br />. Use I-Hooks in lieu of cable tray <br />. Revise quantity of motion sensors <br /> <br />Architectural <br />. Coordinate all above VE efforts with consultant team <br />. Move appliances to FF&E <br />. Front ramp - eliminate 12 feet of ramp and railings <br />. Eliminate faux louver & spandrel glass at mechanical room <br />. Change casework to plastic laminate <br />. Change flush valves/faucets to manual in lieu of sensor <br />. Reduce amount of acoustical panels <br />. Reduce amount of fabric wall covering <br />. Reduce height of ceramic tiles in restrooms <br />. Downgrade Xorel to lesser grade covering <br />. Simplify rear deck and railing <br />. Revise/reduce clerestory glazing <br />. Simplify fin design <br />. Use wood picture rail in lieu of aluminum <br />. Delete frit on tall windows - add shades <br />. Redesign site wall at service yard <br /> <br />Page 3 of 3 <br />