Laserfiche WebLink
44. Dual Plumbing (Purple Pipe) — Dual plumbing is required for this project. The purple <br /> pipes shall be "roughed in" because recycled water service has not yet been extended <br /> into the Downtown area. Recycled water service shall be provided by the City at a later <br /> date at a pressure of 50-55 pounds per square inch at the service meters. The building <br /> shall be designed so that recycled water plumbing fixtures on all floors of the building <br /> and irrigations systems for landscaping properly function at this delivery pressure. <br /> [COA][ENGINEERING] <br /> a. The applicant shall hire an engineer licensed in California and experienced in <br /> the field of wastewater treatment to prepare a report pursuant to California <br /> Water Code section 13522.5 and in accordance with California Code of <br /> Regulations sections 60314 and 60323 (found within Title 22, Division 4, <br /> Chapter 3). The report shall be submitted with the first building submittal, and <br /> will be routed to the Public Works Department for review and coordination. <br /> 45. Recycled Water Facilities — Recycled water facilities shall be provided and designed <br /> in accordance with Engineering Standards for dual plumbing, irrigation, and other <br /> warranted uses per the Recycled Water Ordinance, Chapter 38, Article VIII. Upon a <br /> final determination by the City that recycled water is available for the property, the <br /> applicant shall connect the project to the recycled water system. <br /> [COA][ENGINEERING] <br /> a. If required by Public Works, the applicant shall hire a California licensed <br /> engineer in the field of wastewater treatment to prepare and submit a report <br /> pursuant to California Water Code section 13522.5 and California Code of <br /> Regulations sections 60314 and 60323 (Title 22, Division 4, Chapter 3) prior to <br /> building permit issuance. [COA][PUBLIC WORKS] <br /> 46. Discharge Permit for Subterranean Garages - If the subterranean garage will <br /> necessitate groundwater pumping into the sewer system, a Discharge fee will apply <br /> and a Discharge Permit will be required by Silicon Valley Clean Water (SCVW, formerly <br /> South Bayside System Authority). [SDR][ENGINEERING] <br /> a. In the event that the proposed garage becomes damaged or is otherwise <br /> unusable, a substitute parking supply shall be provided per Article 30.13. <br /> 47. Backflow Protection — Backflow protection on domestic, fire, and irrigation water <br /> services shall be required. The backflow preventer shall be above grade, and shall be <br /> located on private property, accessible to the Public Works division from the outside for <br /> testing. [COA][ENGINEERING] <br /> 48. Fire Flow - The Project shall meet fire flow requirements as established by the Fire <br /> Department which are based on the Fire Code. Fire flow tests are typically performed <br /> during the preliminary design phase but must be completed prior to submittal of final <br /> design. Applicant shall contact the Fire Department for fire flow requirements, and then <br /> submit a written fire flow test request to Engineering. [COA][ENGINEERING] <br /> ATTY/RES0.0027/PC RESO 2075 BROADWAY <br /> REV:04-18-16 VR <br /> Page 12 of 28 <br />