My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
Agmt04 V & A Consulting ... (2)
RedwoodCity
>
City Clerk
>
Agreements
>
2000-2009
>
2004
>
Agmt04 Under $60K
>
Agmt04 V & A Consulting ... (2)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/12/2008 1:41:18 PM
Creation date
8/27/2004 8:35:17 AM
Metadata
Fields
Template:
Agreement
Contractor Name
V & A Consulting Engineering
PROJECT NAME
pro engineering services
RMP File Number
304.5
Date
8/26/2004
Box
6585
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
18
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
<br />Proposal: Topaz Pipeline Corrosion Control System Retrofit <br /> <br />Proposal: <br /> <br />Topaz Pipeline Corrosion Control System <br />Retrofit <br /> <br />Task 1 - System Evaluation <br /> <br />a) A review would be made of the historical information available for the City of Redwood City <br />in terms of the history of corrosion control for the Topaz Pipeline.* <br /> <br />b) Meet with City to review results of initial site visit. * <br /> <br />c) Conduct field testing on existing cathodic protection system for Topaz Line.* <br /> <br />d) Prepare Basis of Design Report which would list the recommended repairs for the existing <br /> <br />cathodic protection system. <br /> <br />* Included in Master Plan Contract. <br /> <br />Task 2 - Prepare Construction Drawings <br /> <br />a) Prepare 90% and [mal plans for the repair of the existing cathodic protection system on <br />Topaz. The drawings would also include any planned additions to the CP system. <br /> <br />b) Prepare 90% and [mal specifications for the repair of the existing cathodic protection system <br />on Topaz. <br /> <br />c) Prepare 90% and [mal estlmate of probable cost for the repalr of the existing cathodic <br />protection system on Topaz. <br /> <br />Deliverables: <br /> <br />One set of bond full size originals and one hard copy of technical specifications <br />and estimate of probable cost. <br />Electronic versions of drawing in AutoCAD, technical specification in Microsoft <br />Word and estimate of probable cost in Microsoft Excel. <br /> <br />Task 3 - Bidding Assistance <br /> <br />a) Replay to Pre Bid questions from contractors. <br /> <br />b) Review Bid Results and provide input to the City. <br /> <br />rfi\ CONSULTING <br />\t:.I ENGINEERS, INC. <br /> <br />(i,'illn!""!,,,c!n,-e ['I(,'.H'IT"II"n <br /> <br />1 <br /> <br />"T <br /> <br />Y" <br /> <br />'t. <br />
The URL can be used to link to this page
Your browser does not support the video tag.