Laserfiche WebLink
<br /> SV ,nt 12/17/87 (#06) <br /> SWC:nt 12/22/87R <br /> building storm drain or storm sewer, a drain connection <br /> shall be extended above the finished grade and jointed <br /> at a point protected from injury. <br /> " , (c) Rainwater piping located underground within <br /> a building shall be of service weight cast iron soil <br /> pipe, Type DWV copper tube, Schedule 40 ABS or PVC, <br /> extra strength vitrified clay pipe, or other approved <br /> materials. Metallic piping shall not be used <br /> underground in those areas underlain by younger bay mud <br /> (see map published by Redwood City Building Division <br /> for approximate locations). <br /> " , (d) Rainwater piping commencing two (2 ) feet <br /> ( . 6m) from the exterior of a building may be of any <br /> approved material permitted in the installation <br /> requirements of this Code.'" <br /> SECTION 6. Article VIII of Chapter 9 of the Rewood City <br /> Code is hereby amended to read as follows: <br /> "ARTICLE VIII. ELECTRICAL CODE" <br /> "DIVISION 1. ADOPTION OF CODE" <br /> IISection 9.110. (a) Pursuant to Section 50022.1, et <br /> seq. , of the Government Code and Section 15 of the Charter <br /> of the City of Redwood City, the National Electrical Code, <br /> 1984 Edition, as published by the National Fire Protection <br /> Association, is hereby adopted and shall be in effect within <br /> the City of Redwood City to the same extent as if set out in <br /> full herein except as expressly amended by the provisions of <br /> this article. <br /> 17 <br /> ---. <br />