My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
Reso PC17-06 0027 PC Reso 612 Jefferson
RedwoodCity
>
City Clerk
>
Resolutions
>
Planning Commission
>
2017
>
Reso PC17-06 0027 PC Reso 612 Jefferson
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/3/2017 8:11:22 AM
Creation date
4/3/2017 8:10:09 AM
Metadata
Fields
Template:
CC Index
CC Index - Document Type
Resolution
Meeting Type
Regular
Agency Type
Planning Commission
Date
3/21/2017
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
23
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
responsible for all fees associated with the performance of the cross -connection <br />control test. [COA] [ENGINEERING] <br />35. Backflow Protection — Backflow protection on all water services is required. The <br />backflow preventer shall be above grade and located on private property, accessible <br />to the Public Works division for testing. [COA][ENGINEERING] <br />36. Fire Flow - The Project shall meet fire flow requirements as established by the Fire <br />Department which are based on the Fire Code. Fire flow tests are typically <br />performed during the preliminary design phase but must be completed prior to <br />submittal of final design. Applicant shall contact the Fire Department for fire flow <br />requirements, and then submit a written fire flow test request to Engineering. <br />[COA][ENGINEERING] <br />37. Stormwater BMPs - Stormwater Pollution Prevention Program Best Management <br />Practices (BMPs) for construction shall be implemented to protect water quality, in <br />accordance with the approved Stormwater Pollution Prevention Plan (SWPPP). BMP <br />plan sheets are available electronically for inserting into project plans. <br />[SDR][ENGINEERING] <br />Street Infrastructure Improvements <br />38. Off -Site Streetscape Improvements — All off-site streetscape improvements shall <br />adhere to City Engineering Standards, and are subject to review and change by the <br />City Landscape Architect. [COA][PLANNING][ENGINEERING] <br />39. Repair or Replace Street Infrastructure - Restore streets surrounding the project <br />site to the satisfaction of the City Engineer at project completion. The Engineer shall <br />approve the preferred layout of pavement and curb markings, and the type and <br />location of parking meters. [SDR][ENGINEERING] <br />40. Parking Garage Ramps - Parking garage ramps shall meet the Design Criteria of <br />the Engineering Standards and consider safety and visibility of pedestrians to the <br />satisfaction of the City Engineer. [SDR][ENGINEERING] <br />41. Shoring for Excavations — No tiebacks shall extend into the public right of way or <br />onto adjacent properties without the written agreement of the City and/or private <br />property owner. Any tie -backs within the City's right of way shall be de -tensioned or <br />removed prior to permit sign -off and/or project acceptance. [COA] [ENGINEERING] <br />Fire and Safetv <br />42. Fire Department Connection — An exterior Fire Department connection shall be <br />provided along the Jefferson Avenue frontage. [COA][FIRE] <br />43. Radio Coverage for Emergency Responders — All building and parking garages <br />shall have approved radio coverage for emergency responders within the building. <br />Upon completion of the building construction, a radio coverage test shall be <br />conducted per the applicable codes and standards and if the test fails an Emergency <br />ATTY/RESO.0027/PC RESO 612 JEFFERSON <br />REV: 03-21-17 PR <br />Page 11 of 22 <br />
The URL can be used to link to this page
Your browser does not support the video tag.