Responders Radio Coverage System shall be installed. Verify any Blue Box phone <br />communication requirements with the Redwood City Police Department. <br />[COA][POLICE] <br />44. Addressing and Access — The following requirements apply: [COA][FIRE] <br />a. Addresses must be logical, sequential numbers, i.e. First Floor 101, 102, <br />103, Second Floor 202, 203, 204, as opposed to F303, G401, etc. <br />b. Floor plan maps shall be submitted with unit numbers at all entrances, <br />excluding fire exits. <br />c. Provide a key pad with 24 hour access code for public safety personnel at <br />the main entrance, as opposed to just RFID readers or similar devices <br />45. Car Stacking Systems — The following notes shall be placed verbatim on the <br />construction plans [COA][FIRE]: <br />Purpose: To establish the requirements for fire protection required for car stacking <br />systems inside buildings to ensure the safe installation of these systems and prevent <br />the spread of fire, should one occur. These requirements are in addition to any other <br />requirements specified in the California Fire Code, NFPA 13, car stacker <br />manufacturer's requirements and recommendations. <br />Definition: Car Stacker — A manual or automatic rack storage system designed to <br />park cars vertically and/or horizontally such that the vehicles are in close proximity to <br />one another and pose an additional hazard due to fire spread. <br />Design Density: Parking areas inside buildings or under attached canopies <br />equipped with car stackers shall be protected by an automatic fire sprinkler system <br />designed to a density of Extra Hazard Group 2. Standard coverage sidewall <br />sprinklers, listed for Ordinary Hazard, shall be provided under each parking level, <br />including the bottom level if the car stacker uses a basement or pit area. The <br />maximum coverage of a sidewall sprinkler is 80 sq. ft. and the use of extended <br />coverage sidewall heads for protection is prohibited. <br />Design Area: The area of application may be reduced, but never less than 1,500 sq. <br />ft., if: <br />a. One-hour rated walls are provided between the stacker parking area and <br />other standard parking stalls or storage areas. <br />b. The car stacker system is divided into maximum 1,500 sq. ft. areas by one- <br />hour fire barriers. <br />NOTE: For hydraulic calculations, flow from all fire sprinklers, upright, <br />pendant and sidewall sprinkler heads, at all levels, located in the area of <br />application, shall be included in the hydraulic calculations. <br />High Rise Buildings: For high rise buildings, the increase in the demand of the fire <br />sprinkler system due to the installation of a car stacker system will increase the <br />ATN/RESO.0027/PC RESO 612 JEFFERSON <br />REV: 03-21-17 PR <br />Page 12 of 22 <br />