My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
Ord84 1889
RedwoodCity
>
City Clerk
>
Ordinances
>
1980-1989
>
1984
>
Ord84 1889
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/5/2005 2:31:10 PM
Creation date
10/7/2004 3:01:37 PM
Metadata
Fields
Template:
CC Index
CC Index - Document Type
Ordinance
Date
1/9/1984
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
29
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
<br /> l. All primary containment shall be product-tight and shall have <br /> overfill protection capacity. <br /> 2. Secondary containment shall comply with the following <br /> requirements: <br /> a. All secondary containment shall be constructed of materials <br /> of s-=tficient thickness, density, and composition so as not to be structurally <br /> " <br /> , <br /> weakened as a result of contact with the discharged hazardous materials and so <br /> as to be capable of containing hazardous materials discharged from a primary <br /> container for a period of time equal to or longer than the maximum <br /> anticipated time sufficient to allow recovery of the discharged hazardous <br /> material. <br /> b. In the event that the storage facility has only one primary <br /> container, the secondary containment shall have the capacity to contain at <br /> least 110 % of the volume of the primary container. <br /> c. In the even t that the storage,facility has more than one <br /> primary container, the secondary container shall have the capacity to contain <br /> 150% of the volume of the largest primary container placed in it, or 10 % of <br /> the aggregate internal volume of all primary containers in the storage <br /> facility, whichever is greater. <br /> 3. In the event that the storage facility is constructed of , <br /> lami na ted, coa ted, or clad materials, such construction shall not comDlv with <br /> the requirements of both primary and secondary containment. <br /> (c) Variance <br /> A variance from the requirement for secondary containment and/or <br /> moni tori ng of a new storage facility may be granted bv the City Council upon <br /> recommendation of the. Chief when: <br /> l. The requi rement of secondary containment creates an unusual and <br /> particular hardship; and .. <br /> (17) <br /> ~-" -"...- <br />
The URL can be used to link to this page
Your browser does not support the video tag.