ATTY/RESO.0033/PC RESO APPROVING A CONDITIONAL USE PERMIT & ARC – 860 CHARTER ST. <br />REV: 06-27-17 PR <br />Page 8 of 11 <br /> <br />not proposing to alter, other than restriping. The work within the City parcel does not <br />create or replace any impervious area, and therefore no C.3 requirements apply to <br />the portion of the project within City jurisdiction. <br /> <br />The work on the County parcel will require stormwater treatment under the C.3 <br />guidelines, and the applicant shall comply with the County’s C.3 requirements for <br />the project based on the impervious surface created/replaced by the entire project. <br />[COA][ENGINEERING] <br />Fire and Safety <br /> 21. Fire Sprinkler - An approved fire sprinkler system shall be installed meeting the <br />requirements of NFPA Standard 13. Location for fire department connections shall be <br />to the satisfaction of the Fire Marshall. <br /> a. All valves controlling the water supply for the automatic fire sprinkler systems, <br />pumps and water flow switches on all fire sprinkler systems shall be <br />automatically supervised. This includes the detector check valves and back-flow <br />prevention devices. <br /> b. Fire alarm water-flow sprinkler signals shall be transmitted to the central <br />station and retransmitted by zone to the public safety communications center. <br /> 22. Fire Flow – The required fire flow at the minimum residual pressure of 20 psi <br />shall be required (IFC Appendix B). The fire flow from a water supply includes both <br />the required fire flow and the demand for the automatic fire sprinkler system. The <br />applicant shall submit a written fire flow test request to Engineering prior to permit <br />issuance. <br /> 23. Fire Alarm Boxes - Manual fire alarm boxes are not required throughout the <br />building when the building is equipment throughout with an automatic fire sprinkler <br />system and notification appliances activate upon sprinkler flow. At least one manual <br />station shall be installed at an approved location. All initiating and indicating devices <br />shall be electronically supervised. <br /> 24. Fire hydrants – The minimum number of fire hydrants and spacing requirements <br />available to the building shall not be less than that listed in the International Fire <br />Code Appendix C. <br /> 25. Key boxes – Key boxes of sufficient size shall be installed at all entrances to the <br />building. These key boxes shall contain sufficient number of keys to allow access to <br />all parts of the building as well as fire protection equipment and systems. <br /> 26. Fire access – Electronic security gates shall be provided with key switches to <br />provide fire department access. Fire department emergency vehicle access shall <br />meet the requirements of the Fire Code for the playground/parking lot located in the <br />County. <br /> <br /> <br />