Agmt05 BKF Engineers
RedwoodCity
>
City Clerk
>
Agreements
>
2000-2009
>
2005
>
Agmt05 Under $60K
>
Agmt05 BKF Engineers
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/5/2009 12:34:43 PM
Creation date
9/1/2005 12:39:49 PM
Metadata
Fields
Template:
Agreement
Contractor Name
BKF Engineers
PROJECT NAME
emergency work - 5th Avenue storm drainage pump station
RMP File Number
304.5
Date
8/29/2005
Amendment
Yes
Box
6586
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
18
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
<br />EXHIBIT "A" <br /> <br />Fifth Avenue Pump Station New Discharge Box Culvert <br />Scope of Work <br /> <br />PHASE I. PRELIMINARY DESIGN <br /> <br />In the preliminary design phase of the Fifth Avenue Pump Station new discharge box culvert <br />emergency construction project, we will further verify the feasibility of constructing about 136 <br />feet of 5' x 5' twin concrete box culvert within the existing 15' storm drain easement. The box <br />culvert will be sized to handle the discharge of the future Fifth Avenue pump station. The <br />existing 42" CMP from the existing storm drain pump station will be connected to the new end <br />wall of the proposed box culvert. Flap gates will be installed at the end of the proposed box <br />culvert next to the Bay Front Canal instead of a discharge structure as designed before. During <br />the preliminary design phase, BKF will fine tune the discharge box culvert, and perform <br />easement survey to locate the existing storm drainage easement in the field. It is our <br />understanding that the City of Redwood City will visually inspect the condition of the existing <br />42" discharge pipe; this information will assist us in our final design. <br /> <br />Task 1 - Preliminary Engineering and Design Development Report <br /> <br />The report will include: <br /> <br />1. Review of existing engineering as-built drawings and reports <br />2. Review existing storm drainage easement and ground survey to locate the 15' easement <br />in field <br />3. Optimizing box culvert design to ensure the proposed structure being saturated within <br />existing easement <br />4. Preliminary engineering of box culvert end wall design to include discharge flap gate and <br />canal level sensor pole <br />5. Proposed box culvert end wall design including existing 42" CMP tie-in <br />6. Permit application from environmental review agencies <br />7. Preparation of preliminary project cost estimate <br />8. Preparation of brief design summary <br />9. Meetings with City staff to review overall preliminary engineering design <br />10. Incorporation of City comments and upgrade final brief design summary <br />11. Project administration including weekly project log <br /> <br />Deliverab les: <br />. Draft brief design summary outlining the twin box culvert design <br />. Finalize brief design summary that incorporates City's comment. Once the City is <br />satisfied with the design summary concept and authorizes us to proceed, BKF will <br />move into working drawings. <br />